Evaluation of multivariate calibration models with different pre-processing and processing algorithms for a novel resolution and quantitation of spectrally overlapped quaternary mixture in syrup

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorMoustafa A.A.
dc.contributor.authorHegazy M.A.
dc.contributor.authorMohamed D.
dc.contributor.authorAli O.
dc.contributor.otherAnalytical Chemistry Department
dc.contributor.otherFaculty of Pharmacy
dc.contributor.otherCairo University
dc.contributor.otherKasr-El Aini Street
dc.contributor.otherCairo
dc.contributor.other11562
dc.contributor.otherEgypt; Analytical Chemistry Department
dc.contributor.otherFaculty of Pharmacy
dc.contributor.otherOctober University for Modern Sciences and Arts (MSA)
dc.contributor.other6th October City11787
dc.contributor.otherEgypt; Analytical Chemistry Department
dc.contributor.otherFaculty of Pharmacy
dc.contributor.otherHelwan University
dc.contributor.otherEin Helwan
dc.contributor.otherCairo
dc.contributor.other11795
dc.contributor.otherEgypt
dc.date.accessioned2020-01-09T20:41:39Z
dc.date.available2020-01-09T20:41:39Z
dc.date.issued2016
dc.descriptionScopus
dc.description.abstractA novel approach for the resolution and quantitation of severely overlapped quaternary mixture of carbinoxamine maleate (CAR), pholcodine (PHL), ephedrine hydrochloride (EPH) and sunset yellow (SUN) in syrup was demonstrated utilizing different spectrophotometric assisted multivariate calibration methods. The applied methods have used different processing and pre-processing algorithms. The proposed methods were partial least squares (PLS), concentration residuals augmented classical least squares (CRACLS), and a novel method; continuous wavelet transforms coupled with partial least squares (CWT-PLS). These methods were applied to a training set in the concentration ranges of 40-100 ?g/mL, 40-160 ?g/mL, 100-500 ?g/mL and 8-24 ?g/mL for the four components, respectively. The utilized methods have not required any preliminary separation step or chemical pretreatment. The validity of the methods was evaluated by an external validation set. The selectivity of the developed methods was demonstrated by analyzing the drugs in their combined pharmaceutical formulation without any interference from additives. The obtained results were statistically compared with the official and reported methods where no significant difference was observed regarding both accuracy and precision. 2015 Elsevier B.V. All rights reserved.en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=24530&tip=sid&clean=0
dc.identifier.doihttps://doi.org/10.1016/j.saa.2015.10.010
dc.identifier.doiPubMed ID 26519913
dc.identifier.issn13861425
dc.identifier.otherhttps://doi.org/10.1016/j.saa.2015.10.010
dc.identifier.otherPubMed ID 26519913
dc.identifier.urihttps://t.ly/3G0Jw
dc.language.isoEnglishen_US
dc.publisherElsevieren_US
dc.relation.ispartofseriesSpectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
dc.relation.ispartofseries154
dc.subjectCarbinoxamineen_US
dc.subjectContinuous wavelet transforms coupled with partial least squares (CWT-PLS)en_US
dc.subjectCyrinol� syrupen_US
dc.subjectEphedrineen_US
dc.subjectMultivariate calibration methodsen_US
dc.subjectPholcodineen_US
dc.subjectAlgorithmsen_US
dc.subjectCalibrationen_US
dc.subjectDrug productsen_US
dc.subjectMixturesen_US
dc.subjectMultivariable systemsen_US
dc.subjectWavelet transformsen_US
dc.subjectCarbinoxamineen_US
dc.subjectEphedrineen_US
dc.subjectMultivariate calibration methodsen_US
dc.subjectPartial least square (PLS)en_US
dc.subjectPholcodineen_US
dc.subjectLeast squares approximationsen_US
dc.subjectazo compounden_US
dc.subjectcarbinoxamineen_US
dc.subjectcodeineen_US
dc.subjectephedrineen_US
dc.subjectFD & C Yellow No. 6en_US
dc.subjectmorpholine derivativeen_US
dc.subjectpholcodineen_US
dc.subjectpyridine derivativeen_US
dc.subjectalgorithmen_US
dc.subjectanalogs and derivativesen_US
dc.subjectcalibrationen_US
dc.subjectevaluation studyen_US
dc.subjectleast square analysisen_US
dc.subjectmultivariate analysisen_US
dc.subjectproceduresen_US
dc.subjectspectrophotometryen_US
dc.subjectAlgorithmsen_US
dc.subjectAzo Compoundsen_US
dc.subjectCalibrationen_US
dc.subjectCodeineen_US
dc.subjectEphedrineen_US
dc.subjectLeast-Squares Analysisen_US
dc.subjectMorpholinesen_US
dc.subjectMultivariate Analysisen_US
dc.subjectPyridinesen_US
dc.subjectSpectrophotometryen_US
dc.titleEvaluation of multivariate calibration models with different pre-processing and processing algorithms for a novel resolution and quantitation of spectrally overlapped quaternary mixture in syrupen_US
dc.typeArticleen_US
dcterms.isReferencedBySweetman, S.C., (2009) Martindale - The Complete Drug Reference, pp. 1236-1237. , (London); Codex Alimentarius (Codex GFSA) Online Updated up to the 37th Session of the Codex Alimentarius Commission 2014 Sunset yellow FCF 110; FDA, (2009) Color Additive Status List; European Medicines Agency, (2007) Guideline on Excipients in the Dossier for Application for Marketing Authorisation of a Medicinal Product; (2014) EU Food Additive Database Sunset Yellow FCF/Orange Yellow S., , Database accessed 6 December; Abbey, J., (2013) Encyclopedia of Food Safety, 2, pp. 459-465. , Colorants H.a. Diseases Academic Press; Shoukrallah, I., (1991) Anal. Lett., 24, pp. 2043-2058; Ramadan, A., Mandil, H., (2006) Anal. Biochem., 353, pp. 133-137; Palabiyik, I.M., Onur, F., (2012) J. Anal. Chem., 67, pp. 56-63; Mansour, A.M., (1997) J. AOAC Int., 81, pp. 958-962; Tang, Y.F., Wu, H.L., Wu, S.M., Chen, S.H., Kou, H.S., (2000) J. Microcolumn Sep., 12, pp. 366-370; Ramadan, A., Antakli, S., Mahmoud, I., (2007) Res. J. Aleppo Univ., 56, p. 97; Bhavani, B.G., Gurupadayya, B., Sharfuddin, S., (2014) J. Appl. Chem., 6, pp. 46-51; Pharmacopoeia, B., (2012) The Stationery Office on Behalf of the Medicines and Healthcare Products Regulatory Agency (MHRA)-� Crown Copyright, I II; Petkovska, A., Babunovska, H., Stefova, M., (2011) Maced. J. Chem. Chem. Eng., 30, pp. 139-150; Zhu, W.-G., Li, M., (2011) Chem. Bioeng., 7, p. 025; Sheng, J., Ping, Q., Lei, J., Ju, H., Song, C., Zhang, D., (2012) Anal. Lett., 45, pp. 652-664; Meadway, C., George, S., Braithwaite, R., (2002) Forensic Sci. Int., 127, pp. 131-135; Denk, O.M., Skellern, G.G., Watson, D.G., (2002) J. Pharmacol. Pharmacother., 54, pp. 87-98; ?ent�rk, Z., Erk, N., �zkan, S.A., Akay, C., Cevhero?lu, ?., (2002) J. Pharm. Biomed., 29, pp. 291-298; Falc�, P.C., Cabeza, A.S., Legua, C.M., (1994) Anal. Lett., 27, pp. 531-547; Okamura, N., Miki, H., Harada, T., Yamashita, S., Masaoka, Y., Nakamoto, Y., Tsuguma, M., Yagi, A., (1999) J. Pharm. Biomed., 20, pp. 363-372; Niemann, R.A., Gay, M.L., (2003) J. Agric. Food Chem., 51, pp. 5630-5638; Phinney, K.W., Ihara, T., Sander, L.C., (2005) J. Chromatogr. A, 1077, pp. 90-97; Marchei, E., Pellegrini, M., Pacifici, R., Zuccaro, P., Pichini, S., (2006) J. Pharm. Biomed. Anal., 41, pp. 1633-1641; Gay, M.L., Niemann, R.A., Musser, S.M., (2006) J. Agric. Food Chem., 54, pp. 285-291; Din�, E., Baydan, E., Kanbur, M., Onur, F., (2002) Talanta, 58, pp. 579-594; Sayar, S., �zdemir, Y., (1998) Food Chem., 61, pp. 367-372; Llamas, N.E., Garrido, M., Nezio, M.S.D., Band, B.S.F., (2009) Anal. Chim. Acta, 655, pp. 38-42; L�pez De Alba, P.L., L�pez Mart�nez, L., De Le�n Rodr�guez, L.M., (2002) Electroanalysis, 14, pp. 197-205; Dominguez, F.B., Diego, F.G., Mendez, J.H., (1990) Talanta, 37, pp. 655-658; Prado, M., Godoy Liq. J, H., (2002) Chromatogr. Relat. Technol., 25, pp. 2455-2472; Diacu, E., Ene, C.P., (2009) Rev. Chim., 60, pp. 745-749; Abdallah, R.M., (2006) Nat. Prod. Sci., 12, pp. 55-61; Brereton, R.G., (2000) Analyst, 125, pp. 2125-2154; Brereton, R.G., (1997) Analyst, 122, pp. 1521-1529; Lundstedt, T., Seifert, E., Abramo, L., Thelin, B., Nystrom, A., Pettersen, J., Bergman, R., (1998) Chemom. Intell. Lab. Syst., 42, pp. 3-40; Hoang, V.D., (2014) Trends Anal. Chem., 62, pp. 144-153; Graps, A., (1995) IEEE Comput. Sci. Eng., 2, pp. 50-61; Walczak, B., (2000) Wavelets in Chemistry, , Elsevier Press Amsterdam, The Netherlands; Daubechies, I., (1992) Ten Lectures on Wavelets, Society for Industrial and Applied Mathematics, , (Philadelphia); Hegazy, M., Yehia, A., Moustafa, A.A., Die Pharmazie-An (2013) Int. J. Pharm. Sci., 68, pp. 317-326; Brereton, R.G., (2003) Chemometrics: Data Analysis for the Laboratory and Chemical Plant, , Wiley; Din�, E., �zdemir, A., Baleanu, D., (2005) Talanta, 65, pp. 36-47; Kramer, R., (1998) Chemometric Techniques for Quantitative Analysis, , Marcel Dekker Inc. New York; Donahue, S., Brown, C., Caputo, B., Modell, M., (1988) Anal. Chem., 60, pp. 1873-1878; Martens, H., Naes, T., (1989) Multivariate Calibration: A User-friendly Guide to Multivariate Calibration and Classification, , John Wiley & Sons New York; Pham-Gia, T., Duong, Q., (1989) J. Math. Comput. Modell., 12, pp. 1613-1625; Haaland, D.M., Thomas, E.V., (1988) Anal. Chem., 60, pp. 1193-1202; Melgaard, D.K., Haaland, D.M., Wehlburg, C.M., (2002) Appl. Spectrosc., 56, pp. 615-624; Dm, H., Ev, T., (1988) Anal. Chem., 60, pp. 1202-1211; Wold, S., (1995) Chemom. Intell. Lab. Syst., 30, pp. 109-115; Andrade-Garda, M., (2013) Basic Chemometric Techniques in Atomic Spectroscopy, , 2nd ed. Royal Society of Chemistry UK; Smilde, A., Bro, R., Geladi, P., (2004) Multi-way Analysis in Chemistry and Related Fields, , John Wiley & Sons, Ltd; ICH, Validation of analytical procedures: Text and methodology Q2(Rl) (2005) International Conference on Harmonization, , (Geneva)
dcterms.sourceScopus

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
avatar_scholar_256.png
Size:
6.31 KB
Format:
Portable Network Graphics
Description: