Evaluation of multivariate calibration models with different pre-processing and processing algorithms for a novel resolution and quantitation of spectrally overlapped quaternary mixture in syrup

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorMoustafa A.A.
dc.contributor.authorHegazy M.A.
dc.contributor.authorMohamed D.
dc.contributor.authorAli O.
dc.contributor.otherOctober University for Modern Sciences and Arts (MSA)
dc.date.accessioned2020-01-09T20:41:39Z
dc.date.available2020-01-09T20:41:39Z
dc.date.issued5-2-2016
dc.descriptionSJR 2025 0.683 Q1 H-Index 179 Subject Area and Category: Chemistry Analytical Chemistry Spectroscopy Physics and Astronomy Atomic and Molecular Physics, and Optics Instrumentation
dc.description.abstractA novel approach for the resolution and quantitation of severely overlapped quaternary mixture of carbinoxamine maleate (CAR), pholcodine (PHL), ephedrine hydrochloride (EPH) and sunset yellow (SUN) in syrup was demonstrated utilizing different spectrophotometric assisted multivariate calibration methods. The applied methods have used different processing and pre-processing algorithms. The proposed methods were partial least squares (PLS), concentration residuals augmented classical least squares (CRACLS), and a novel method; continuous wavelet transforms coupled with partial least squares (CWT-PLS). These methods were applied to a training set in the concentration ranges of 40-100 ?g/mL, 40-160 ?g/mL, 100-500 ?g/mL and 8-24 ?g/mL for the four components, respectively. The utilized methods have not required any preliminary separation step or chemical pretreatment. The validity of the methods was evaluated by an external validation set. The selectivity of the developed methods was demonstrated by analyzing the drugs in their combined pharmaceutical formulation without any interference from additives. The obtained results were statistically compared with the official and reported methods where no significant difference was observed regarding both accuracy and precision. en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=24530&tip=sid&clean=0
dc.identifier.citationMoustafa, A. A., Hegazy, M. A., Mohamed, D., & Ali, O. (2016). Evaluation of multivariate calibration models with different pre-processing and processing algorithms for a novel resolution and quantitation of spectrally overlapped quaternary mixture in syrup. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 154, 76–83. https://doi.org/10.1016/j.saa.2015.10.010 ‌
dc.identifier.doihttps://doi.org/10.1016/j.saa.2015.10.010
dc.identifier.issn13861425
dc.identifier.otherhttps://doi.org/10.1016/j.saa.2015.10.010
dc.identifier.urihttps://t.ly/3G0Jw
dc.language.isoEnglishen_US
dc.publisherElsevieren_US
dc.relation.ispartofseriesSpectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy ; Volume 154, 2016, Pages 76-83
dc.subjectCarbinoxamine; Continuous wavelet transforms coupled with partial least squares (CWT-PLS); Cyrinol® syrup; Ephedrine; Multivariate calibration methods; Pholcodine.en_US
dc.titleEvaluation of multivariate calibration models with different pre-processing and processing algorithms for a novel resolution and quantitation of spectrally overlapped quaternary mixture in syrupen_US
dc.typeArticleen_US
dcterms.sourceScopus

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
avatar_scholar_256.png
Size:
6.31 KB
Format:
Portable Network Graphics
Description: