The Induced Changes in the Bulk Etch Rate and the Thermal Stability of PADC by the Effect of Long Storing Time at Room Temperature and Heat Treatment
dc.Affiliation | October University for modern sciences and Arts (MSA) | |
dc.contributor.author | Shoeib, M. Y | |
dc.contributor.author | Mokhtar, S. M | |
dc.date.accessioned | 2019-12-26T10:00:42Z | |
dc.date.available | 2019-12-26T10:00:42Z | |
dc.date.issued | 2019-01 | |
dc.description | Accession Number: WOS:000464970100006 | en_US |
dc.description.abstract | The samples of poly allyl diglycol carbonate PADC (CR-39) (stored and fresh samples) polymer track detectors have been heated at different annealing temperatures and different annealing times. The thermal stability has been studied for different annealed samples; it was also examined as a function of the storage time. The percentage degree of crystallinity has been studied for different annealed samples and stored samples. The samples were etched in 6 M KOH solution at 70 degrees C for 3 h. The variation of bulk etch rate of isochronal annealed samples has been studied. The results indicate an improvement in the thermal stability of Poly allyl diglycol carbonate PADC; where the bulk etch rate increases with the increase in the annealing temperature and annealing time. The storage time has no noticeable effect on the bulk etch rate of un-annealed samples, though the thermal stability of PADC improved with increasing the storage time. | en_US |
dc.identifier.doi | https://doi.org/10.21608/ajnsa.2018.2917.1058 | |
dc.identifier.issn | 1110-0451 | |
dc.identifier.other | https://doi.org/10.21608/ajnsa.2018.2917.1058 | |
dc.identifier.uri | https://ajnsa.journals.ekb.eg/article_20273_a3913bafca44396b891d8daccb1d9f40.pdf | |
dc.language.iso | en | en_US |
dc.publisher | EGYPTIAN SOC NUCLEAR SCIENCES & APPLICATIONS | en_US |
dc.relation.ispartofseries | EGYPTIAN SOC NUCLEAR SCIENCES & APPLICATIONS, 1 ELHAMY STR, GARDEN CITY, PO BOX 192, CAIRO, 11016, EGYPT;Volume: 52 Issue: 1 Pages: 44-55 | |
dc.relation.uri | https://cutt.ly/3rrUXhx | |
dc.subject | University for TRACKS | en_US |
dc.subject | CR-39 | en_US |
dc.subject | Activation energy | en_US |
dc.subject | Thermal stability | en_US |
dc.subject | Storage time | en_US |
dc.subject | Annealing temperature | en_US |
dc.subject | CR-39 | en_US |
dc.title | The Induced Changes in the Bulk Etch Rate and the Thermal Stability of PADC by the Effect of Long Storing Time at Room Temperature and Heat Treatment | en_US |
dc.type | Article | en_US |