dc.descriptionSJR 2024 0.291 Q3 H-Index 67 Subject Area and Category: Chemistry Analytical Chemistry Medicine Medicine (miscellaneous)
dc.description.abstractHigh-performance liquid chromatography (HPLC), ultra-performance liquid chromatography (UPLC) and rapid resolution liquid chromatographic (RRLC) methods have been developed and validated for the separation and quantitation of both or either of two ternary mixtures present in ophthalmic solutions. The first mixture contains chloramphenicol, dexamethasone sodium phosphate and tetryzoline HCl (TZH); while the second one contains ofloxacin, prednisolone acetate and TZH. Both preparations contain benzalkonium chloride as a preservative. The columns used were a HPLC column (C18 5 µm particle size), a RRLC column (C18 2.6 µm particle size) and a UPLC column (C18 1.7 µm particle size). A comparative study was conducted to illustrate the effect of the change in column particle size and dimensions on the other chromatographic conditions, backpressure and the separation of both ternary mixtures. The methods were validated as per ICH guidelines where accuracy, repeatability, interday precision and robustness were found to be within the acceptable limits. The RRLC column provided shorter run time and better resolution than HPLC, while the UPLC column gave the shortest run time for all columns. The RRLC column resulted in minimum backpressure, so it could be used with any HPLC instrument, which makes the method more practical and economic. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed.en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=24023&tip=sid&clean=0
dc.identifier.citationSalem, H., Hassan, N. Y., Lotfy, H. M., & Saleh, S. S. (2014). Column Performance Study of Different Variants of Liquid Chromatographic Technique: An Application on Pharmaceutical Ternary Mixtures Containing Tetryzoline. Journal of Chromatographic Science, 53(5), 708–715. https://doi.org/10.1093/chromsci/bmu109 ‌
dc.identifier.doihttps://doi.org/10.1093/chromsci/bmu109
dc.identifier.issn219665
dc.identifier.otherhttps://doi.org/10.1093/chromsci/bmu109
dc.identifier.urihttps://t.ly/DXZpY
dc.language.isoEnglishen_US
dc.publisherOxford University Pressen_US
dc.relation.ispartofseriesJournal of Chromatographic Science; , Volume 53, Issue 5, 2015, Pages 708–715
dc.titleColumn performance study of different variants of liquid chromatographic technique: An application on pharmaceutical ternary mixtures containing tetryzolineen_US
dc.typeArticleen_US
dcterms.sourceScopus

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
chromsci.bmu109.fullsarachroma.pdf
Size:
268.12 KB
Format:
Adobe Portable Document Format