Anions Selective Electrodes with Unusual Half Nernstian Response
dc.Affiliation | October University for modern sciences and Arts (MSA) | |
dc.contributor.author | M. Riad, Safa'a | |
dc.contributor.author | R. Rezk, Mamdouh | |
dc.contributor.author | I. Khattab, Fatma | |
dc.contributor.author | K. Abd El-Rahman, Mohamed | |
dc.contributor.author | M. Marzouk, Hoda | |
dc.date.accessioned | 2020-02-02T08:27:13Z | |
dc.date.available | 2020-02-02T08:27:13Z | |
dc.date.issued | 2014 | |
dc.description | MSA Google Scholar | en_US |
dc.description.abstract | Selective poly (vinylchloride) membrane electrodes based on a quaternary ammonium compound, malachite green as a novel ion exchanger for anionic species were prepared. The developed membrane electrodes were used successfully for the quantification of sulphadimethoxine, iodide ions and thiocyante ions in their pure powdered forms, fish water and/or pharmaceutical formulation. Linear responses were obtained within a concentration range of 10-5-10-2 M for the three selected monovalent anionic species. The electrodes exhibited unusual half Nernstian slopes when the divalent cationic malachite green is used as a novel lipophilic ion exchanger in PVC based membranes for determination of monovalent anions. They have fast response times about 20 s, satisfactory reproducibility, and long life times. | en_US |
dc.description.sponsorship | UNIV TEHRAN, FAC CHEMISTRY, CENTER EXCELLENCE ELECTROCHEMISTRY | en_US |
dc.description.uri | https://www.scimagojr.com/journalsearch.php?q=21100224440&tip=sid&clean=0 | |
dc.identifier.citation | Response Mechanism of Ion‐Selective Electrodes Based on a Guanidine Ionophore: An Apparently ‘Two‐Thirds Nernstian’ Response Slope Article Nov 2007Electroanalysis Secil KoseogluChun‐Ze LaiChad Ferguson Philippe Buhlmann View Show abstract Ion-Selective Electrodes With Ionophore-Doped Sensing Membranes Chapter Mar 2012 Philippe Buhlmann Li Chen View Show abstract “Coated Wire Lead (II) Selective Potentiometric Sensor based on 4-tert-butylcalix [6]arene.” Vaishali S. Bhat, Vijaykumar S. Ijeri and Ashwini K. Srivastava, Sensors & Actuators: B. Chemical, 99 (2004) 98–105. Article Full-text available Apr 2004SENSOR ACTUAT B-CHEM Vaishali S. Bhat Vijaykumar Ijeri Ashwini Srivastava View Show abstract A Generalized Model for Apparently “Non-Nernstian” Equilibrium Responses of Ionophore-Based Ion-Selective Electrodes. 1. Independent Complexation of the Ionophore with Primary and Secondary Ions Article Jul 2003ANAL CHEM Shigeru Amemiya Philippe BuhlmannKazunori Odashima View Show abstract Potentiometric Response of Modified Carbon Paste Electrode Based on Mixed Ion‐Exchangers Article Dec 2007Electroanalysis Hazem M Abu-Shawish View Show abstract Apparently “Non-Nernstian” Equilibrium Responses Based on Complexation Between the Primary Ion and a Secondary Ion in the Liquid ISE Membrane Article Jul 1999Electroanalysis Philippe BuhlmannYoshio Umezawa View Show abstract Analysis of malachite green and crystal violet in fish with bilinear model Article Apr 2009FOOD CHEM Jintao YuanLi-Fu LiaoXi-Lin XiaoShu-Qin Gao View Show abstract Ion-Selective Electrodes with Unusual Response Functions: Simultaneous Formation of Ionophore-Primary Ion Complexes with Different Stoichiometries Article Nov 2011Anal Chem Masafumi Miyake Li Chen Gianluca Pozzi Philippe Buhlmann View Show abstract Origin of Non-Nernstian Anion Response Slopes of Metalloporphyrin-Based Liquid/Polymer Membrane Electrodes Article Jan 2001ANAL CHEM Erich D. Steinle Shigeru Amemiya Philippe BuhlmannMark E. Meyerhoff View Show abstract Direct Evidence of Ionic Fluxes Across Ion-Selective Membranes: A Scanning Electrochemical Microscopic and Potentiometric Study Article Jun 2001ANAL CHEM Róbert E GyurcsányiÉva PergelRenáta Nagy Erno Lindner View Show abstract Improving the Detection Limit of Anion-Selective Electrodes: An Iodide-Selective Membrane with a Nanomolar Detection Limit Article Sep 2003ANAL CHEM | en_US |
dc.identifier.doi | https://doi.org/ | |
dc.identifier.other | https://doi.org/ | |
dc.identifier.uri | https://t.ly/5MRLP | |
dc.language.iso | en | en_US |
dc.publisher | UNIV TEHRAN, FAC CHEMISTRY, CENTER EXCELLENCE ELECTROCHEMISTRY | en_US |
dc.relation.ispartofseries | ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY;Volume: 6 Issue: 4 Pages: 392-402 | |
dc.subject | University of Anions Selective Electrodes | en_US |
dc.title | Anions Selective Electrodes with Unusual Half Nernstian Response | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- avatar_scholar_256.png
- Size:
- 6.31 KB
- Format:
- Portable Network Graphics
- Description:
- Faculty Of Pharmacy Research Paper
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 51 B
- Format:
- Item-specific license agreed upon to submission
- Description: