A validated liquid chromatography-tandem mass spectrometric method for the determination of co-administered ranitidine and metronidazole in plasma of human volunteers†
dc.Affiliation | October University for modern sciences and Arts (MSA) | |
dc.contributor.author | El-Naem, Omnia A | |
dc.contributor.author | El-Maraghy, Christine M | |
dc.date.accessioned | 2021-06-27T10:00:57Z | |
dc.date.available | 2021-06-27T10:00:57Z | |
dc.date.issued | 6/21/2021 | |
dc.description | Scopus | en_US |
dc.description.abstract | This work describes the development, optimization and validation of a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for the simultaneous analysis of co-administered ranitidine (RAN) and metronidazole (MET) in plasma of healthy human volunteers. A simple protein precipitation procedure using 1 mL acetonitrile was applied to extract both drugs and metoclopramide as an internal standard (IS) from plasma. The chromatographic separation was achieved on a C18 column with isocratic elution of the mobile phase consisting of acetonitrile and 0.1% formic acid (90 : 10, v/v) at a flow rate of 0.35 mL min−1. The positive ionization mode was used for detecting the ions, by observing the pairs of transition m/z 314.82 < 176.06 for RAN, m/z 172.03 < 127.95 for MET and m/z 299.86 < 277.10 for IS. The linearity range was from 5–600 ng mL−1 for RAN and 2–40 μg mL−1 for MET. The method was found to be sensitive and accurate with good simple extraction recovery and matrix effect, according to FDA guidelines for bioanalytical methods. The developed method could be applied for further bioavailability studies that could be useful in therapeutic drug monitoring. | en_US |
dc.description.uri | https://www.scimagojr.com/journalsearch.php?q=19700175229&tip=sid&clean=0 | |
dc.identifier.doi | https://doi.org/10.1039/d1ay00284h | |
dc.identifier.issn | 17599660 | |
dc.identifier.other | https://doi.org/10.1039/d1ay00284h | |
dc.identifier.uri | https://qrgo.page.link/zEfTz | |
dc.language.iso | en_US | en_US |
dc.publisher | Royal Society of Chemistry | en_US |
dc.relation.ispartofseries | Analytical Methods.;Volume 13, Issue 23, Pages 2586 - 2595 | |
dc.subject | Acetonitrile | en_US |
dc.subject | Bioactivity | en_US |
dc.subject | High pressure liquid chromatography | en_US |
dc.subject | Mass spectrometers | en_US |
dc.subject | Mass spectrometry | en_US |
dc.subject | Patient monitoring | en_US |
dc.subject | Positive ions Bioanalytical methods | en_US |
dc.subject | Bioavailability study | en_US |
dc.subject | Chromatographic separations | en_US |
dc.subject | spectrometric | en_US |
dc.subject | Therapeutic drug monitoring Drug products. | en_US |
dc.subject | Extraction recovery | en_US |
dc.subject | Protein precipitation | en_US |
dc.subject | Simultaneous analysis | en_US |
dc.subject | Tandem mass | en_US |
dc.title | A validated liquid chromatography-tandem mass spectrometric method for the determination of co-administered ranitidine and metronidazole in plasma of human volunteers† | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- avatar_scholar_256.png.jpg.jpg
- Size:
- 1.89 KB
- Format:
- Joint Photographic Experts Group/JPEG File Interchange Format (JFIF)
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 51 B
- Format:
- Item-specific license agreed upon to submission
- Description: