On-line coupling of derivatization with pre-concentration to determine trace levels of methotrexate
| dc.Affiliation | October University for modern sciences and Arts (MSA) | |
| dc.contributor.author | Emara S. | |
| dc.contributor.author | Masujima T. | |
| dc.contributor.author | Zarad W. | |
| dc.contributor.author | Kamal M. | |
| dc.contributor.author | El-Bagary R. | |
| dc.contributor.other | October University for modern sciences and Arts MSA | |
| dc.date.accessioned | 2020-01-09T20:42:30Z | |
| dc.date.available | 2020-01-09T20:42:30Z | |
| dc.date.issued | 2012-10-26 | |
| dc.description | SJR 2024 1.452 Q1 H-Index 60 | |
| dc.description.abstract | A new simple, sensitive and precise green analytical procedure using an automated packed-reactor derivatization technique coupled with on-line solid-phase enrichment (SPEn) has been developed and evaluated to determine trace levels of methotrexate (MTX). The method was based on injection of MTX into a flowing stream of phosphate buffer (0.04 M, pH 3.4), carried through the packed oxidant reactor of Cerium (IV) trihydroxyhydroperoxide for oxidative cleavage of the drug into highly fluorescent product, 2,4-diaminopteridine-6-carboxylic acid, followed by SPEn on a head of short ODS column (10 mm×4.6 mm i.d., 5 μm particle size). The flow rate was 0.25 mL/min and packed reactor temperature was 40 °C. The trapped product was back-flush eluted from the ODS column to the detector by column-switching with an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 5:95 (v/v). The eluent was monitored at emission and excitation wavelengths of 460 and 360 nm, respectively. The calibration curve was linear over the concentration range of 1.25–50 ng/mL with a detection limit of 0.08 ng/mL. The method was successfully applied to determine MTX in pharmaceutical formulations with mean percentage recovery ranging from 99.48 to 99.60. | en_US |
| dc.description.uri | https://www.scimagojr.com/journalsearch.php?q=19900192116&tip=sid&clean=0 | |
| dc.identifier.citation | Emara, S., Masujima, T., Zarad, W., Kamal, M., & EL-Bagary, R. (2013). On-line coupling of derivatization with pre-concentration to determine trace levels of methotrexate. Journal of Pharmaceutical Analysis, 3(1), 28–35. https://doi.org/10.1016/j.jpha.2012.10.003 | |
| dc.identifier.doi | https://doi.org/10.1016/j.jpha.2012.10.003 | |
| dc.identifier.issn | 20951779 | |
| dc.identifier.other | https://doi.org/10.1016/j.jpha.2012.10.003 | |
| dc.identifier.uri | https://t.ly/7OGyb | |
| dc.language.iso | English | en_US |
| dc.publisher | Xi'an Jiaotong University | en_US |
| dc.relation.ispartofseries | Journal of Pharmaceutical Analysis ; Volume 3, Issue 1, 2013, Pages 28-35 | |
| dc.subject | MethotrexateFlow injection analysisCerium (IV) trihydroxyhydroperoxideOn-line solid-phase enrichmentFluorescence detection | en_US |
| dc.title | On-line coupling of derivatization with pre-concentration to determine trace levels of methotrexate | en_US |
| dc.type | Article | en_US |
| dcterms.source | Scopus |