On-line coupling of derivatization with pre-concentration to determine trace levels of methotrexate

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorEmara S.
dc.contributor.authorMasujima T.
dc.contributor.authorZarad W.
dc.contributor.authorKamal M.
dc.contributor.authorEl-Bagary R.
dc.contributor.otherOctober University for modern sciences and Arts MSA
dc.date.accessioned2020-01-09T20:42:30Z
dc.date.available2020-01-09T20:42:30Z
dc.date.issued2012-10-26
dc.descriptionSJR 2024 1.452 Q1 H-Index 60
dc.description.abstractA new simple, sensitive and precise green analytical procedure using an automated packed-reactor derivatization technique coupled with on-line solid-phase enrichment (SPEn) has been developed and evaluated to determine trace levels of methotrexate (MTX). The method was based on injection of MTX into a flowing stream of phosphate buffer (0.04 M, pH 3.4), carried through the packed oxidant reactor of Cerium (IV) trihydroxyhydroperoxide for oxidative cleavage of the drug into highly fluorescent product, 2,4-diaminopteridine-6-carboxylic acid, followed by SPEn on a head of short ODS column (10 mm×4.6 mm i.d., 5 μm particle size). The flow rate was 0.25 mL/min and packed reactor temperature was 40 °C. The trapped product was back-flush eluted from the ODS column to the detector by column-switching with an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 5:95 (v/v). The eluent was monitored at emission and excitation wavelengths of 460 and 360 nm, respectively. The calibration curve was linear over the concentration range of 1.25–50 ng/mL with a detection limit of 0.08 ng/mL. The method was successfully applied to determine MTX in pharmaceutical formulations with mean percentage recovery ranging from 99.48 to 99.60.en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=19900192116&tip=sid&clean=0
dc.identifier.citationEmara, S., Masujima, T., Zarad, W., Kamal, M., & EL-Bagary, R. (2013). On-line coupling of derivatization with pre-concentration to determine trace levels of methotrexate. Journal of Pharmaceutical Analysis, 3(1), 28–35. https://doi.org/10.1016/j.jpha.2012.10.003 ‌
dc.identifier.doihttps://doi.org/10.1016/j.jpha.2012.10.003
dc.identifier.issn20951779
dc.identifier.otherhttps://doi.org/10.1016/j.jpha.2012.10.003
dc.identifier.urihttps://t.ly/7OGyb
dc.language.isoEnglishen_US
dc.publisherXi'an Jiaotong Universityen_US
dc.relation.ispartofseriesJournal of Pharmaceutical Analysis ; Volume 3, Issue 1, 2013, Pages 28-35
dc.subjectMethotrexateFlow injection analysisCerium (IV) trihydroxyhydroperoxideOn-line solid-phase enrichmentFluorescence detectionen_US
dc.titleOn-line coupling of derivatization with pre-concentration to determine trace levels of methotrexateen_US
dc.typeArticleen_US
dcterms.sourceScopus