On-line coupling of derivatization with pre-concentration to determine trace levels of methotrexate

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorEmara S.
dc.contributor.authorMasujima T.
dc.contributor.authorZarad W.
dc.contributor.authorKamal M.
dc.contributor.authorEl-Bagary R.
dc.contributor.otherPharmaceutical Chemistry Department
dc.contributor.otherFaculty of Pharmacy
dc.contributor.otherMisr International University
dc.contributor.otherKm 28 Ismailia Road
dc.contributor.otherCairo
dc.contributor.otherEgypt; Analytical Molecular Medicine and Devices Laboratory
dc.contributor.otherHiroshima University
dc.contributor.otherGraduate School of Biomedical Sciences
dc.contributor.other1-2-3
dc.contributor.otherKasumi
dc.contributor.otherMinami-ku
dc.contributor.otherHiroshima 734-8551
dc.contributor.otherJapan; Pharmaceutical Analytical Chemistry Department
dc.contributor.otherFaculty of Pharmacy
dc.contributor.otherModern Sciences and Arts University
dc.contributor.other26 July Mehwar Road intersection with Wahat Road
dc.contributor.other6 October City
dc.contributor.otherEgypt; Pharmaceutical Chemistry Department
dc.contributor.otherFaculty of Pharmacy
dc.contributor.otherCairo University
dc.contributor.otherKasr El Aini St.
dc.contributor.otherCairo 11562
dc.contributor.otherEgypt
dc.date.accessioned2020-01-09T20:42:30Z
dc.date.available2020-01-09T20:42:30Z
dc.date.issued2013
dc.descriptionScopus
dc.description.abstractA new simple, sensitive and precise green analytical procedure using an automated packed-reactor derivatization technique coupled with on-line solid-phase enrichment (SPEn) has been developed and evaluated to determine trace levels of methotrexate (MTX). The method was based on injection of MTX into a flowing stream of phosphate buffer (0.04 M, pH 3.4), carried through the packed oxidant reactor of Cerium (IV) trihydroxyhydroperoxide for oxidative cleavage of the drug into highly fluorescent product, 2,4-diaminopteridine-6- carboxylic acid, followed by SPEn on a head of short ODS column (10 mm�4.6 mm i.d., 5 ?m particle size). The flow rate was 0.25 mL/min and packed reactor temperature was 40 �C. The trapped product was back-flush eluted from the ODS column to the detector by column-switching with an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 5:95 (v/v). The eluent was monitored at emission and excitation wavelengths of 460 and 360 nm, respectively. The calibration curve was linear over the concentration range of 1.25-50 ng/mL with a detection limit of 0.08 ng/mL. The method was successfully applied to determine MTX in pharmaceutical formulations with mean percentage recovery ranging from 99.48 to 99.60. � 2013 Xi'an Jiaotong University.en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=19900192116&tip=sid&clean=0
dc.identifier.doihttps://doi.org/10.1016/j.jpha.2012.10.003
dc.identifier.doiPubMed ID :
dc.identifier.issn20951779
dc.identifier.otherhttps://doi.org/10.1016/j.jpha.2012.10.003
dc.identifier.otherPubMed ID :
dc.identifier.urihttps://t.ly/7OGyb
dc.language.isoEnglishen_US
dc.publisherXi'an Jiaotong Universityen_US
dc.relation.ispartofseriesJournal of Pharmaceutical Analysis
dc.relation.ispartofseries3
dc.subjectCerium (IV) trihydroxyhydroperoxideen_US
dc.subjectFlow injection analysisen_US
dc.subjectFluorescence detectionen_US
dc.subjectMethotrexateen_US
dc.subjectOn-line solid-phase enrichmenten_US
dc.subjectbufferen_US
dc.subjectcarboxylic acid derivativeen_US
dc.subjectceriumen_US
dc.subjecthydroperoxide derivativeen_US
dc.subjectmethotrexateen_US
dc.subjectphosphateen_US
dc.subjectarticleen_US
dc.subjectconcentration (parameters)en_US
dc.subjectderivatizationen_US
dc.subjectdrug determinationen_US
dc.subjectelutionen_US
dc.subjectflow rateen_US
dc.subjectfluorescence analysisen_US
dc.subjectlimit of detectionen_US
dc.subjectoxidationen_US
dc.subjectparticle sizeen_US
dc.subjectpHen_US
dc.subjectsolid phase extractionen_US
dc.titleOn-line coupling of derivatization with pre-concentration to determine trace levels of methotrexateen_US
dc.typeArticleen_US
dcterms.isReferencedByBleyer, W.A., The clinical pharmacology of methotrexate: New applications of an old drug (1978) Cancer, 41, pp. 36-51; B?rc?, M., Ilie, M., Baconi, D.L., Spectrofluorimetric methotrexate assay in human plasma (2010) Farmacia, 58, pp. 95-101; Sabry, S.M., Abdel-Hady, M., Elsayed, M., Study of stability of methotrexate in acidic solution. Spectrofluorimetric determination of methotrexate in pharmaceutical preparations through acid-catalyzed degradation reaction (2003) J. Pharm. Biomed. Anal., 32, pp. 409-423; Espinosa-Mansilla, A., Dur�n Mer�s, I., Madera, A.Z., Kinetic fluorimetric determination of the antineoplastic methotrexate (MTX) in human serum (2002) J. Pharm. Biomed. Anal., 29, pp. 851-858; Hayashi, H., Fujimaki, C., Tsuboi, S., Application of fluorescence polarization immunoassay for determination of methotrexate-polyglutamates in rheumatoid arthritis patients (2008) Tohoku J. Exp. Med., 215, pp. 95-101; Cheng, H.L., Chiou, S.S., Liao, Y.M., Analysis of methotrexate and its eight metabolites in cerebrospinal fluid by solid-phase extraction and triple-stacking capillary electrophoresis (2010) Anal. Bioanal. Chem., 398, pp. 2183-2190; Cheng, H.L., Liao, Y.M., Chiou, S.S., On-line stacking capillary electrophoresis for analysis of methotrexate and its eight metabolites in whole blood (2008) Electrophoresis, 29, pp. 3665-3673; Fang, S., Lollo, C.P., Derunes, C., Development and validation of a liquid chromatography method for simultaneous determination of three process-related impurities: Yeastolates, triton X-100 and methotrexate (2011) J. Chromatogr. B, 879, pp. 3612-3619; Klapkova, E., Kukacka, J., Kotaska, K., The influence of 7-OH methotrexate metabolite on clinical relevance of methotrexate determination (2011) Clin. Lab., 57, pp. 599-606; Michail, K., Moneeb, M.S., Determination of methotrexate and indomethacin in urine using SPE-LC-DAD after derivatization (2011) J. Pharm. Biomed. Anal., 55, pp. 317-324; Hu, L., Liu, Y., Cheng, S., Simultaneous determination of six analytes by HPLC-UV for high throughput analysis in permeability assessment (2011) J. Chromatogr. Sci., 49, pp. 124-128; Sartori, T., Seigi Murakami, F., Cruz, A.P., Development and validation of a fast RP-HPLC method for determination of methotrexate entrapment efficiency in polymeric nanocapsules (2008) J. Chromatogr. Sci., 46, pp. 505-509; El-Hady, D.A., El-Maali, N.A., Gotti, R., Methotrexate determination in pharmaceuticals by enantioselective HPLC (2005) J. Pharm. Biomed. Anal., 37, pp. 919-925; Uchiyama, M., Matsumoto, T., Matsumoto, T., Simple and sensitive HPLC method for the fluorometric determination of methotrexate and its major metabolites in human plasma by post-column photochemical reaction (2012) Biomed. Chromatogr., 26, pp. 76-80; Van Haandel, L., Stobaugh, J.F., Bioanalytical method development for a generation 5 polyamidoamine folic acid methotrexate conjugated nanoparticle (2010) Anal. Bioanal. Chem, 397, pp. 1841-1852; Chen, S., Zhang, Z., Molecularly imprinted solid-phase extraction combined with electrochemical oxidation fluorimetry for the determination of methotrexate in human serum and urine (2008) Spectrochim. Acta A, 70, pp. 36-41; Li, H., Luo, W., Zeng, Q., Method for the determination of blood methotrexate by high performance liquid chromatography with online post-column electrochemical oxidation and fluorescence detection (2007) J. Chromatogr. B, 845, pp. 164-168; Dur�n Mer�s, I., Espinosa Mansilla, A., Rodr�guez G�mez, M.J., Determination of methotrexate, several pteridines, and creatinine in human urine, previous oxidation with potassium permanganate, using HPLC with photometric and fluorimetric serial detection (2005) Anal. Biochem., 346, pp. 201-209; McCrudden, E.A., Tett, S.E., Improved high-performance liquid chromatography determination of methotrexate and its major metabolite in plasma using a poly(styrene- divinylbenzene) column (1999) J. Chromatogr. B, 721, pp. 87-92; Yu, Z., Westerlund, D., Boose, K.S., Determination of methotrexate and its metabolite 7-hydroxymethotrexate by direct injection of human plasma into a column-switching liquid chromatographic system using post-column photochemical reaction with fluorimetric detection (1997) J. Chromatogr. B, 689, pp. 379-386; Suzuki, T., Hashimoto, H., Ichinose, N., Microanalysis of methotrexate by high-performance liquid chromatography using a fluorescence detector (1995) Fresenius J. Anal. Chem., 351, pp. 806-807; Kubo, H., Umiguchi, Y., Fukumoto, M., Fluorimetric determination of methotrexate in serum by high-performance liquid chromatography using in-line oxidation with hydrogen peroxide (1992) Anal. Sci., 8, pp. 789-792; �alamoun, J., Smr�, M., Kiss, F., Column liquid chromatography of methotrexate and its metabolites using a post-column photochemical reactor and fluorescence detection (1987) J. Chromatogr., 419, pp. 213-223; �alamoun, J., Franti�ek, K., Determination of methotrexate and its metabolites 7-hydroxymethotrexate and 2,4-diamino-N10-methylpteroic acid in biological fluids by liquid chromatography with fluorimetric detection (1986) J. Chromatogr., 378, pp. 173-181; Nelson, J.A., Harris, B.A., Decker, W.J., Analysis of methotrexate in human plasma by high-performance liquid chromatography with fluorescence detection (1977) Cancer Res., 37, pp. 3970-3973; (2005) The Official Compendia of Standards, pp. 1248-1250. , The United States Pharmacopeia and National Formulary Asian Edition, USP 28-NF 23 The United States Pharmacopeial Convention Inc., Rockville, MD; Chen, S., Zhang, Z., He, D., Flow-injection-electrochemical oxidation fluorimetry for determination of methotrexate (2007) Luminescence, 22, pp. 338-342; Emara, S., Determination of methotrexate in pharmaceutical formulations by flow injection analysis exploiting the reaction with potassium permanganate (2004) Farmaco, 59, pp. 827-833; Stefan, R.I., Bokretsion, R.G., Van Staden, J.F., Simultaneous determination of L- and D-methotrexate using a sequential injection analysis/amperometric biosensors system (2003) Biosensors Bioelectron., 19, pp. 261-267; Emara, S., Razee, S., El-Shorbagy, A.-N., Flow injection method for the determination of methotrexate with a column-packed oxidizing agent (1996) Analyst, 121, pp. 183-188; Saleh, T.A., Sensing of chlorpheniramine in pharmaceutical applications by sequential injector coupled with potentiometer (2011) J. Pharm. Anal., 1, pp. 246-250
dcterms.sourceScopus

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
avatar_scholar_256.png
Size:
6.31 KB
Format:
Portable Network Graphics
Description:
Loading...
Thumbnail Image
Name:
main.pdf
Size:
466.87 KB
Format:
Adobe Portable Document Format
Description: