A comparative study of validated spectrophotometric and TLC- spectrodensitometric methods for the determination of sodium cromoglicate and fluorometholone in ophthalmic solution

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorSaleh S.S.
dc.contributor.authorLotfy H.M.
dc.contributor.authorHassan N.Y.
dc.contributor.authorElgizawy S.M.
dc.contributor.otherOctober University for Modern Sciences and Arts (MSA)
dc.date.accessioned2020-01-09T20:42:22Z
dc.date.available2020-01-09T20:42:22Z
dc.date.issued2012-11-17
dc.descriptionSJR 2024 0.677 Q2 H-Index 85
dc.descriptionSubject Area and Category: Pharmacology, Toxicology and Pharmaceutics Pharmaceutical Science Pharmacology
dc.description.abstractThe determination of sodium cromoglicate (SCG) and fluorometholone (FLU) in ophthalmic solution was developed by simple, sensitive and precise methods. Three spectrophotometric methods were applied: absorptivity factor (a-Factor method), absorption factor (AFM) and mean centering of ratio spectra (MCR). The linearity ranges of SCG were found to be (2.5-35 μg/mL) for (a-Factor method) and (MCR); while for (AFM), it was found to be (7.5-50 μg/mL). The linearity ranges of FLU were found to be (4-16 μg/mL) for (a-Factor method) and (AFM); while for (MCR), it was found to be (2-16 μg/mL). The mean percentage recoveries/RSD for SCG were found to be 100.31/0.90, 100.23/0.57 and 100.43/1.21; while for FLU, they were found to be 100.11/0.56, 99.97/0.35 and 99.94/0.88 using (a-Factor method), (AFM) and (MCR), respectively. A TLC-spectrodensitometric method was developed by separation of SCG and FLU on silica gel 60 F254 using chloroform:methanol:toluene:triethylamine in the ratio of (5:2:4:1 v/v/v/v) as developing system, followed by spectrodensitometric measurement of the bands at 241 nm. The linearity ranges and the mean percentage recoveries/RSD were found to be (0.4-4.4 μg/band), 100.24/1.44 and (0.2-1.6 μg/band), 99.95/1.50 for SCG and FLU, respectively. A comparative study was conducted between the proposed methods to discuss the advantage of each method. The suggested methods were validated in compliance with the ICH guidelines and were successfully applied for the determination of SCG and FLU in their laboratory prepared mixtures and commercial ophthalmic solution in the presence of benzalkonium chloride as a preservative. These methods could be an alternative to different HPLC techniques in quality control laboratories lacking the required facilities for those expensive techniques.en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=22205&tip=sid&clean=0
dc.identifier.citationSaleh, S. S., Lotfy, H. M., Hassan, N. Y., & El-Gizawy, S. M. (2013). A comparative study of validated spectrophotometric and TLC- spectrodensitometric methods for the determination of sodium cromoglicate and fluorometholone in ophthalmic solution. Saudi Pharmaceutical Journal, 21(4), 411–421. https://doi.org/10.1016/j.jsps.2012.11.001 ‌
dc.identifier.doihttps://doi.org/10.1016/j.jsps.2012.11.001
dc.identifier.issn13190164
dc.identifier.otherhttps://doi.org/10.1016/j.jsps.2012.11.001
dc.identifier.urihttps://t.ly/KXMGp
dc.language.isoEnglishen_US
dc.relation.ispartofseriesSaudi Pharmaceutical Journal; Volume 21, Issue 4 , Pages 411-421
dc.subjectAbsorption factor; Absorptivity factor; Fluorometholone; Mean centering; Sodium cromoglicate; TLC- spectrodensitometric.en_US
dc.titleA comparative study of validated spectrophotometric and TLC- spectrodensitometric methods for the determination of sodium cromoglicate and fluorometholone in ophthalmic solutionen_US
dc.typeArticleen_US
dcterms.sourceScopus

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S1319016412000977-main.pdf
Size:
982.88 KB
Format:
Adobe Portable Document Format