The power of High Impact Amplitude Manipulation (HIAM) technique for extracting the basic spectra of two Fixed-dose combinations (FDC) -Spectrophotometric purity analysis via spectral contrast angle

Loading...
Thumbnail Image

Date

15/02/2022

Journal Title

Journal ISSN

Volume Title

Type

Article

Publisher

Elsevier

Series Info

Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy.;Volume 27315 May 2022 Article number 121036

Abstract

HIAM technique allows the extraction of the original constant signal of each single component out of interference signals of a mixture and further transformed into basic spectrum (D0 ). It includes the meth- ods: ratio subtraction coupled with unified constant subtraction (RS-UCS), constant center (CC) and con- stant extraction (CE). The technique was introduced for the analysis of two pharmaceutical formulations used to treat cardiovascular diseases. The formulations are binary combinations of Amlodipine (AML) with either Atorvastatin (ATR) or Candesartan (CND) which shows interefernce absorbance signals. The technique was valid over the linearity range of (5.0–35.0 mg/ml) for AML, ATR and CND with recovery per- centage 100.40 ± 1.88 , 100.00 ± 0.86 and 99.83 ± 1.07, respectively . The extracted signals were tested for its purity by spectral contrast angle (cos h) to illustrate the efficency of the HIAM technique where cos h values ranges from (0.9902 to 0.9986). The presented technique was fully validated regarding ICH guide- lines and were statistically compared using one-way ANOVA at 95% confidence.

Description

Scopus

Keywords

Ratio subtraction, Constant center, Constant extraction, Amlodipine, Atorvastatin, Candesartan

Citation