KPI-based standards benchmarking for the preference of different analytical approaches developed for simultaneous determination of ciprofloxacin and hydrocortisone: A SWOT case study

dc.AffiliationOctober University for modern sciences and Arts MSA
dc.contributor.authorNessim, Christine
dc.contributor.authorEl Hamd, Mohamed
dc.contributor.authorObaydo, Reem
dc.contributor.authorSaleh, Sarah
dc.contributor.authorLotfy, Hayam
dc.date.accessioned2024-08-17T11:28:02Z
dc.date.available2024-08-17T11:28:02Z
dc.date.issued2024-08
dc.description.abstractThis study aims to prefer the suitability of an analytical approach developed for simultaneously determining ciprofloxacin hydrochloride (CIP) and hydrocortisone (HYD) in their ear drop dosage form. The preference between the three known instruments was utilized, namely UV-spectrophotometry, reversed phase-high-performance liquid chromatography (RP-HPLC)-UV, and thin-layer chromatography (TLC)-densitometry. The instrumentational studies determined that the mathematical UV methods (utilized various manipulation designs such as the isoabsorptive point, absorbance ratio, extended ratio subtraction, ratio difference, and mean centering of ratio spectra) had linearities in the range of 2.0–14.0 and 1.0–14.0 µg·mL−1 , the RPHPLC-UV method showed a linearity range of 1.0–8.0 µg·mL−1 , and the TLC-spectrodensitometric method had linearity ranges of 0.2–1.6 µg/band and 0.6–2.0 µg/band for both CIP and HYD, respectively. The analytical performance, validity, and greenness of the approaches were evaluated through the benchmarking of key performance indicator (KPI)-based standards and a SWOT (strengths, weaknesses, opportunities, and threats) analysis. The KPIs and SWOT study focused on several aspects, including (1) the selectivity and robustness of the methods, (2) sensitivity, (3) accuracy and precision, (4) applicability, (5) whiteness, (6) greenness, and (7) blueness. However, the assessment of whiteness, greenness, and blueness was conducted using well-known ecological assessment tools such as the RGB12 Algorithm, Analytical Eco-Scale, AGREE, GAPI, and Blue Applicability Grade Index. In conclusion, based on the findings, UV-spectrophotometry emerged as the most practically convenient approach. It demonstrated advantages based on the predetermined KPI-based standards. Furthermore, UV-spectrophotometry was deemed to be the most environmentally friendly option.en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=84944&tip=sid&clean=0
dc.identifier.doihttps://doi.org/10.1515/revac-2023-0077
dc.identifier.otherhttps://doi.org/10.1515/revac-2023-0077
dc.identifier.urihttp://repository.msa.edu.eg/xmlui/handle/123456789/6131
dc.language.isoenen_US
dc.publisherWalter de Gruyter GmbHen_US
dc.relation.ispartofseriesReviews in Analytical Chemistry;2024; 43: 20230077
dc.subjectciprofloxacin, hydrocortisone, UV-spectrophotometry, RP-HPLC-UV, TLC-densitometry, KPIs-based standards, SWOT analysisen_US
dc.titleKPI-based standards benchmarking for the preference of different analytical approaches developed for simultaneous determination of ciprofloxacin and hydrocortisone: A SWOT case studyen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
KPI-based_standards_benchmarking_for_the_preferenc.pdf
Size:
2.17 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
51 B
Format:
Item-specific license agreed upon to submission
Description: