The biological complication of implant abutment materials. A systematic review and meta-analysis
dc.Affiliation | October University for modern sciences and Arts (MSA) | |
dc.contributor.author | Mokhtar M.A. | |
dc.contributor.author | Elnagar G. | |
dc.contributor.author | Saleh M. | |
dc.contributor.author | Radwan M.M. | |
dc.contributor.other | Department of Fixed Prosthodontics | |
dc.contributor.other | Faculty of Dentistry | |
dc.contributor.other | MSA University | |
dc.contributor.other | Egypt; Department of Fixed Prosthodontics | |
dc.contributor.other | Faculty of Dentistry | |
dc.contributor.other | Cairo University | |
dc.contributor.other | Egypt; Department of Fixed Prosthodontics | |
dc.contributor.other | Faculty of Oral and Dental Medicine | |
dc.contributor.other | Hodeidah University | |
dc.contributor.other | Yemen; Department of Fixed Prosthodontics | |
dc.contributor.other | Faculty of Dentistry | |
dc.contributor.other | Beni-suef University | |
dc.contributor.other | Egypt | |
dc.date.accessioned | 2020-01-09T20:40:57Z | |
dc.date.available | 2020-01-09T20:40:57Z | |
dc.date.issued | 2018 | |
dc.description | Scopus | |
dc.description.abstract | Aim The goal of this review was to identify the biological complication of implant abutment materials in relation to alveolar bone around implant-supported superstructure. Methodology An electronic database search and a further manual search were directed to select RCTs, and cohort studies that give evidence about different abutment materials complication. Pocket depth, amount of rescission and crestal bone loss were attributed to alveolar bone loss. Results Fourteen clinical studies were selected from an initial search of 107 studies and the extraction of the analysis data were tabled according to complication output. Pocket probing depth were documented in eight studies, PPD around Zirconium implant abutments was 3.2 mm versus 3.4 mm for Titanium abutments. Five studies examined the recession index for Zirconium and Titanium implant abutments. The RI ranged from 0 to 0.4 at Titanium implant abutments and 0 to 0.3 at Zirconium implant abutments. Alveolar bone loss around Zirconia abutments was reported to differ from 0.2-1.48 mm and 0.3-1.43mm at Titanium abutments. Conclusion The data reported in this systematic review did not give an evidence for the complication regarding all ceramic versus metallic implant abutment. However, it can be concluded that the assessment of the randomized clinical trials did not provide an absolute decision for the choice of ceramic or metallic as implant abutment material in relation to alveolar bone response. The meta-analysis presented a statistically significant difference between abutment material with superiority for the all ceramic abutments over metallic abutment providing a favorable response of Marginal Bone Loss, but non-statistically significant regarding Pocket Probing Depth and Recession Index of soft tissue. � ariesdue March 2018; 10(1) 23. | en_US |
dc.description.uri | https://www.scimagojr.com/journalsearch.php?q=21100226806&tip=sid&clean=0 | |
dc.identifier.doi | https://doi.org/10.23805/JO.2018.10.01.04 | |
dc.identifier.doi | PubMed ID : | |
dc.identifier.issn | 2036413X | |
dc.identifier.other | https://doi.org/10.23805/JO.2018.10.01.04 | |
dc.identifier.other | PubMed ID : | |
dc.identifier.uri | https://t.ly/7M2pE | |
dc.language.iso | English | en_US |
dc.publisher | Ariesdue | en_US |
dc.relation.ispartofseries | Journal of Osseointegration | |
dc.relation.ispartofseries | 10 | |
dc.subject | October University for Modern Sciences and Arts | |
dc.subject | جامعة أكتوبر للعلوم الحديثة والآداب | |
dc.subject | University of Modern Sciences and Arts | |
dc.subject | MSA University | |
dc.subject | Crestal bone loss | en_US |
dc.subject | Implant abutments | en_US |
dc.subject | Pocket depth | en_US |
dc.subject | Recession | en_US |
dc.subject | Titanium | en_US |
dc.subject | Zirconia | en_US |
dc.title | The biological complication of implant abutment materials. A systematic review and meta-analysis | en_US |
dc.type | Review | en_US |
dcterms.isReferencedBy | Siddiqi, A., Kieser, J.A., De Silva, R.K., Thomson, W.M., Duncan, W.J., Soft and hard tissue response to zirconia versus titanium one-piece implants placed in alveolar and palatal sites: A randomized control trial (2015) Clin Implant Dent Related Res, 17, pp. 483-496; Payer, M., Heschl, A., Koller, M., Arnetzl, G., Lorenzoni, M., Jakse, N., All-ceramic restoration of zirconia two-piece implants - A randomized controlled clinical trial (2015) Cl Oral Impl Res, 26, pp. 371-376; Jung, R.E., Holderegger, C., Sailer, I., Khraisat, A., Suter, A., Hammerle, C.H., The effect of all-ceramic and porcelain-fused-to-metal restorations on marginal periimplant soft tissue color: A randomized controlled clinical trial Int J Pe. Rest Dent, 28, pp. 357-365. , 200; Belser, U.C., Schmid, B., Higginbottom, F., Buser, D., Outcome analysis of implant restorations located in the anterior maxilla: A review of the recent literature (2004) Int J Oral Max Implants, 19, pp. 30-42; Ekfeldt, A., F�rst, B., Carlsson, G.E., Zirconia abutments for single-tooth implant restorations: A retrospective and clinical follow-up study (2011) Clin Oral Implants Res, 22 (11), pp. 1308-1314. , Nov; Glauser, R., Sailer, I., Wohlwend, A., Studer, S., Schibli, M., Scharer, P., Experimental zirconia abutments for implant-supported singletooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study (2004) Int J Prosth, 17, pp. 285-290; Canullo, L., Clinical outcome study of customized zirconia abutments for singleimplant restorations (2007) Int J Prosthodontics, 20, pp. 489-493; Andersson, B., Taylor, A., Lang, B.R., Scheller, H., Sch�rer, P., Sorensen, J.A., Tarnow, D., Alumina ceramic implant abutments used for single-tooth replacement: A prospective 1- to 3-year multicenter study (2001) Int J Prosthodont, 14 (5), pp. 432-438. , Sep- Oct; Park, S.E., Da Silva, J.D., Weber, H.P., Ishikawa-Nagai, S., Optical phenomenon of periimplant soft tissue. Part I. Spectrophotometric assessment of natural tooth gingiva and periimplant mucosa (2007) Cl Oral Impl Res, 18, pp. 569-574; Lops, D., Bressan, E., Chiapasco, M., Rossi, A., Romeo, E., Zirconia and titanium implant abutments for single-tooth implant prostheses after 5 years of function in posterior regions (2013) Int J Oral Max Implants, 28, pp. 281-287; Zembic, A., Bosch, A., Jung, R.E., Hammerle, C.H., Sailer, I., Five-year results of a randomized controlled clinical trial comparing zirconia and titanium abutments supporting single-implant crowns in canine and posterior regions (2013) Cl Oral Impl Res, 24, pp. 384-390; De Alboroz, C.A., Vignoletti, F., Ferrantino, L., Cardenas, E., De, S.M., Sanz, M., A randomized trial on the aesthetic outcomes of implant-supported restorations with zirconia or titanium abutments (2014) J Clin Period, 41, pp. 1161-1169; Follmann, D., Elliott, P., Suh, I., Cutler, J., Variance imputation for overviews of clinical trials with continuous response (1992) J Clin Epid, 45 (7), pp. 769-773; Lops, D., Bressan, E., Parpaiola, A., Luca, S., Cecchinato, D., Romeo, E., Soft tissues stability of cad-cam and stock abutments in anterior regions: 2-year prospective multicentric cohort study Clin Oral Implants Res 2015 Dec, 26 (12), pp. 1436-1442; Do Nascimento, C., Sucena Pita, M., De Souza Santos, E., Monesi, N., Faria Ribeiro, R., Microbiome of titanium and zirconia dental implants abutments (2016) Dental Materials, 32 (1), pp. 93-101; Yogesh, V., Jain, V., Chauhan, S.S., Bharate, V., Koli, D., Kumar, M., Influence of different forms and materials (zirconia or titanium) of abutments in peri-implant softtissue healing using matrix metalloproteinase-8: A randomized pilot study (2017) J Prosthet Dent, 118 (4), pp. 475-480. , Oct; Sailer, I., Zembic, A., Jung, R.E., Siegenthaler, D., Holderegger, C., Hammerle, C.H., Randomized controlled clinical trial of customized zirconia and titanium implant abutments for canine and posterior single-tooth implant reconstructions: Preliminary results at 1 year of function (2009) Cl Oral Impl Res, 20, pp. 219-225; Zembic, A., Sailer, I., Jung, R.E., Hammerle, C.H., Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results (2009) Clin Oral Impl Res, 20, pp. 802-808; Zembic, A., Philipp, A.O., Hammerle, C.H., Wohlwend, A., Sailer, I., Eleven-year followup of a prospective study of zirconia implant abutments supporting single allceramic crowns in anterior and premolar regions (2015) Clin Implant Dent Relat Res, 17, pp. e417-e426. , Oct; Linkevicius, T., Apse, P., Influence of abutment material on stability of peri-implant tissues: A systematic review (2008) Inter J Oral Maxill Implants, 23, pp. 449-456; Van Brakel, R., Noordmans, H.J., Frenken, J., De Roode, R., De Wit, G.C., Cune, M.S., The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissues Clin Oral Impl Res, 22, pp. 1172-1178. , 201; Nothdurft, F.P., Fontana, D., Ruppenthal, S., May, A., Aktas, C., Mehraein, Y., Lipp, P., Kaestner, L., Differential behavior of fibroblasts and epithelial cells on structured implant abutment materials: A comparison of materials and surface topographies (2015) Clin Implant Dent Relat Res, 17 (6), pp. 1237-1249. , Dec; Hosseini, M., Worsaae, N., Schiodt, M., Gotfredsen, K., A 1-year randomised controlled trial comparing zirconia versus metal-ceramic implant supported single-tooth restorations (2011) Eur J Oral Impl, 4, pp. 347-361; Hosseini, M., Worsaae, N., Schiodt, M., Gotfredsen, K., A 3-year prospective study of implant-supported, single-tooth restorations of all-ceramic and metalceramic materials in patients with tooth agenesis (2013) Clin Oral Impl Res, 24, pp. 1078-1087; Gapski, R., Neugeboren, N., Pomeranz, A.Z., Reissner, M.W., Endosseous implant failure influenced by crown cementation: A clinical case report (2008) Int J Oral Maxillofacial Implants, 23, pp. 943-946; Wilson, T.G., Jr., The positive relationship between excess cement and peri-implant disease: A prospective clinical endoscopic study (2009) J Periodontol, 80, pp. 1388-1392; Linkevicius, T., Vindasiute, E., Puisys, A., Peciuliene, V., The influence of margin location on the amount of undetected cement excess after delivery of cementretained implant restorations (2011) Clin Oral Implants Res, 22, pp. 1379-1384; Balasubramaniam, G.R., Predictability of resin bonded bridges - A systematic review (2017) Br Dent J, 222 (11), pp. 849-858. , Jun; Mascarenhas, F., Yilmaz, B., McGlumphy, E., Clelland, N., Seidt, J., Load to failure of different zirconia implant abutments with titanium components (2017) J Prosthet Dent, 117 (6), pp. 749-754. , Jun; Ralph, V., Cune, M.S., Van Winkelhoff, A.J., De Putter, C., Verhoeven, J.W., Van Der Reijden, W., Early bacterial colonization and soft tissue health around zirconia and titanium abutments: An in vivo study in man (2011) Clin Oral Implants Res, 22 (6), pp. 571-577. , Jun; Belser, U.C., Schmid, B., Higginbottom, F., Buser, D., Outcome analysis of implant restorations located in the anterior maxilla: A review of the recent literature (2004) Int J Oral Maxillofacial Implants, 19, pp. 30-42; Buchi, D.L.E., Sailer, I., Fehmer, V., Hammerle, C.H.F., Thoma, D.S., All-ceramic singletooth implant reconstructions using modified zirconia abutments: A prospective randomized controlled clinical trial of the effect of pink veneering ceramic on the esthetic outcome (2014) Int J Periodontics Restorative Dent, 34, pp. 29-37; Br�gger, U., Karoussis, I., Persson, R., Pjetursson, B., Salvi, G., Lang, N.P., Technical and biological complications/ failures with single crowns and fixed partial dentures in implants: A 10-year prospective cohort study (2005) Clin Oral Implants Res, 16, pp. 326-334; De Boever, A.L., Keersmaekers, K., Vanmaele, G., Kerschbaum, T., Theuniers, G., De Boever, J.A., Prosthetic complications in fixed endosseous implant-borne reconstructions after an observation period of at least 40 months (2006) J Oral Rehabilitation, 33, pp. 833-839; Ekfeldt, A., Furst, B., Carlsson, G.E., Zirconia abutments for single-tooth implant restorations: A retrospective and clinical follow-up study (2011) Clin Oral Implant Res, 22, pp. 1308-1314; Nakamura, K., Kanno, T., Milleding, P., Ortengren, U., Zirconia as a dental implant abutment material: A systematic review (2010) Int J Prosthodontics, 23, pp. 299-309; Muche, R., Krausse, A., Strub, J.R., Success rates of implant supported prostheses in partially edentulous patients - Part II (2003) Schweizerische Monatsschrift f�r Zahnmedizin, 113, pp. 404-410; Passos, S.P., Linke, B., Larjava, H., French, D., Performance of zirconia abutments for implant-supported single-tooth crowns in esthetic areas: A retrospective study up to 12-year followup (2014) Clinical Oral Implants Research; Pjetursson, B.E., Tan, K., Lang, N.P., Br�gger, U., Egger, M., Zwahlen, M., A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. I. Implant-supported FPDs (2004) Clin Oral Implants Res, 15 (6), pp. 625-642. , Dec; Sailer, I., Philipp, A., Zembic, A., Pjetursson, B.E., Hammerle, C.H., Zwahlen, M., A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions (2009) Clinical Oral Implants Research, pp. 4-31; Vigolo, P., Givani, A., Majzoub, Z., Cordioli, G., A 4-year prospective study to assess periimplant hard and soft tissues adjacent to titanium versus gold-alloy abutments in cemented single implant crowns (2006) J Prosthod, 15, pp. 250-256 | |
dcterms.source | Scopus |