Energy Analysis of Recuperated Gas Turbine Cycles with Mist Blade Cooling

Thumbnail Image

Date

2016

Journal Title

Journal ISSN

Volume Title

Type

Book chapter

Publisher

AMER SOC MECHANICAL ENGINEERS

Series Info

ASME Turbo Expo: Turbine Technical Conference and Exposition;Article Number: UNSP V003T20A001

Doi

Scientific Journal Rankings

Abstract

The present work investigates the effects of mist injection in turbine blade cooling line and the investigation parameters on the performance parameters. The investigation parameters are ambient temperature, ambient relative humidity, and compressor pressure ratio and turbine inlet temperature. The performance parameters are coolant ratio, plant efficiency, heat regeneration rate and specific fuel consumption. This study is conducted on simple recuperated cycle (SRC), recuperated cycle with closed loop cooling (RCCLC) and recuperated cycle with film cooling (RCFC). The results show that by mist, the compressor pressure ratio can be extended to 11 to achieve optimum efficiency. The plant efficiency of RCCLC increases by 2.5% than that for SRC.

Description

Accession Number: WOS:000384850100052

Keywords

University for Energy analysis, gas turbine, mist, recuperated cycle

Citation

Cited References in Web of Science Core Collection: 22