Characterization and thermal stability of gamma irradiated CR-39 polymer

Thumbnail Image

Date

2015

Journal Title

Journal ISSN

Volume Title

Type

Article

Publisher

EDP SCIENCES

Series Info

EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS;Volume: 70 Issue: 1 Article Number: 10201

Scientific Journal Rankings

Abstract

The thermal behavior of pristine sample and gamma irradiated PADC (CR-39) polymer has been studied using thermogravimetric analysis. The changes in degradation activation energy and entropy of activation have been studied as a consequence of gamma irradiation. Water uptake of pristine sample and the effect of UV absorption have also been studied. CR-39 registers a weak effect of thermal stability for different gamma doses applied, while the etching process shows noticeable reduction in thermal stability of CR-39. The chemical structure of CR-39 detector registers high stability with gamma ray and UV of short wave length.

Description

Accession Number: WOS:000354786500004

Keywords

University for RACK DETECTORS, STATE

Citation

Cited References in Web of Science Core Collection: 15