Analysis and Mitigation of Harmonics Caused by Air Conditioners in a Distribution System

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorFarrag, Mohamed Emad
dc.contributor.authorHaggag, Ayman
dc.contributor.authorFarooq, Haroon
dc.contributor.authorAli, Waqas
dc.date.accessioned2019-12-15T12:15:24Z
dc.date.available2019-12-15T12:15:24Z
dc.date.issued2017
dc.descriptionAccession Number: WOS:000428724000105en_US
dc.description.abstractDue to the rise in power electronic based appliances and loads in distribution systems, grave concerns about the harmonic distortion level in the power system network are growing. Consequently, it became essential for the sustainable and robust design of a distribution system that the intensity of the harmonic pollution caused by different non-linear loads at residential level should be investigated. In addition, it is also of extreme importance to mitigate these harmonic distortions using new techniques. Thus, this paper is considering the Air Conditioners (ACs) load; which is a particularly swiftly escalating load, with nonlinearity, in hot areas and this results in harmonics contaminations. Therefore, this paper simulates a model of the harmonics distortion of air conditioners using ETAP software for the simulation of a low voltage network in Pakistan as an example of a warm territory. The results of this investigation confirm an alarming level of harmonic distortion in Pakistani distribution systems. Furthermore, the work introduces and implements a harmonics mitigation technique to considerably minimize the harmonic pollution using power conditioners.en_US
dc.description.sponsorshipIEEE Egypt Sect; IEEE Power & Energy Soc, Egypt Chapter; PELS, Egypt Chapteren_US
dc.identifier.citationCited References in Web of Science Core Collection: 15en_US
dc.identifier.issn2573-3044
dc.identifier.urihttps://ieeexplore.ieee.org/document/8301258
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.ispartofseriesProceedings of the International Middle East Power Systems Conference;Pages: 702-707
dc.relation.urihttps://t.ly/vneDq
dc.subjectUniversity of Air Conditioner; Harmonic Distortion; Distribution System; Power Conditioneren_US
dc.titleAnalysis and Mitigation of Harmonics Caused by Air Conditioners in a Distribution Systemen_US
dc.typeArticleen_US