Occupational exposure to staff during endoscopic retrograde cholangiopancreatography in Sudan

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorSulieman, A
dc.contributor.authorElzaki, M
dc.contributor.authorKhalil, Mohamed
dc.date.accessioned2020-01-29T11:25:33Z
dc.date.available2020-01-29T11:25:33Z
dc.date.issued2011
dc.descriptionMSA Google Scholaren_US
dc.description.abstractEndoscopic retrograde cholangiopancreatography (ERCP) procedure is an invasive technique that requires fluoroscopic and radiographic exposure. The purpose of this study was to determine the occupational dose of ionising radiation at three gastroenterology departments (Fedial, Soba and Ibn seena hospitals) in Khartoum, Sudan. The radiation dose was measured during 55 therapeutic ERCP procedures. Thermoluminescence dosemeters were used. The mean radiation dose for the first operator was 0.27 mGy for the eye lens, 0.21 for the thyroid, 0.32 for the chest, 0.17 for the hand and 0.22 for the leg. The mean radiation dose for the second operator was 0.21 mGy for the hand and 0.20 mGy for the chest, while the mean radiation dose for the nurse was 0.44 mGy for the hand and 0.19 for the chest. The radiation dose received by the staff in these hospitals was found to be higher than most of the values in the literature. The radiation absorbed dose received by the different organs is relatively low. Additional studies need to be conducted for radiation dose optimisation.en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=29514&tip=sid&clean=0
dc.identifier.citationStephen E. R.. , Handbook of Gastro Intestinal and Genitourinary Radiology, 1992, vol. Vols. 6–8 first edn. mosby-st. Louispg. 145 2 Naidu L., Singhal S., Preece D., Vohrah A., Loft D.. Radiation exposure to personnel performing endoscopic retrograde cholangiopancreatography, Postgrad. Med. J., 2005, vol. 81 (pg. 660-662) Google ScholarCrossrefPubMed 3 The Society of Interventional RadiologyInterventional fluoroscopy, reducing radiation risks for patient and staff, 2005(pg. 1-5) 05–5286 4 Wall B. F., Fisher E. S., Shrimpton P. C., Rae S.. Current levels of gonadal irradiation from a selection of routine diagnostic X-ray examinations in Great Britain, 1980HMSO NRPB-R105 5 International Commission of Radiological Protection 1990Recommendations of the International Commission of Radiological Protection, 1991Pergamon Press ICRP 60 6 Campbell N., Sparrow K., Fortier M., Ponich T.. Practical radiation safety and protection for endoscopist during ERCP, Gastrointest. Endosc., 2007, vol. 55 4(pg. 552-557) Google ScholarCrossref 7 Sulieman A., Paroutoglou G., Kapsoritakis A., Kapatenakis A., Potamianos S., Vlychou M., Theodorou K.. Radiation exposure to examiners and patients during therapeutic ERCP: dose optimisation and risk estimation, 2008n: Tenth National Conference on Biomedical Physics and Engineering16–18 OctoberBulgaria, Sofia 8 Larkin C., Workman A., Wright R. E. R., Tham C. K. T.. Radiation doses to patients during ERCP, Gastrointest. Endosc., 2001, vol. 53 (pg. 161-164) Google ScholarCrossrefPubMed 9 Tsalafoutas I. A., Paraskeva K. D., Yakoumakis E. N., Vassilaki A. E., Maniatis P. N., Karagiannis J. A., Koulentianos E. D.. Radiation doses to patients from endoscopic retrograde cholangiopancreatography examinations and image quality considerations, Radiat. Prot. Dosim., 2003, vol. 106 3(pg. 241-246) Google ScholarCrossref 10 Heyd R. L., Kopecky K. K., Sherman S., Lehman G. A., Stockberger S. M.. Radiation exposure to patients and personnel during interventional ERCP at a teaching institution, Gastrointest. Endosc., 1996, vol. 44 (pg. 287-292) Google ScholarCrossrefPubMed 11 Chen M., Swearingen F., Richard M., Ott D.. Radiation exposure during ERCP: effect of a protective shield., Gastrointest. Endosc., 1996, vol. 43 (pg. 1-5) Google ScholarCrossrefPubMed 12 Buls N., Pages J., Mana F., Osteaux M.. Patient and staff exposure during endoscopic retrograde cholangiopancreatography, Br. J. Radiol., 2002, vol. 75 (pg. 435-443) Google ScholarCrossrefPubMed 13 Singhal A., Rowe G., Faizallah R.. Pulse fluoroscopy in ERCP: reducing radiation exposure, Gastrointest. Endosc., 2006, vol. 63 5pg. AB 300 Google ScholarCrossref 14 Li A., Lee D., Wong W., Chan A.. Experience of endoscopists and radiation exposure to patients during ERCP, Gastrointest. Endosc., 2004, vol. 59 5pg. 122 Google ScholarCrossref 15 Martin C. J., Sutton D. G., Workman A., Shaw A. J., Tempeton D.. Protocol for measurement of patient entrance surface dose rates for fluoroscopic X-ray equipment, Br. J. Radiol., 1998, vol. 71 (pg. 1283-1287) Google ScholarCrossrefPubMed 16 Sulieman A., Theodorou K., Vlychou M., Topaltzikis T., Kanavou D., Fezoulidis I., Kappas C.. Radiation dose measurement and risk estimation for paediatric patients undergoing micturating cystourethrography, Br. J. Radiol., 2007, vol. 80 (pg. 731-737) Google ScholarCrossrefPubMed 17 Johlin F. C., Pelsang R. E., Mary Greenleaf R. N.. Phantom study to determine radiation exposure to medical personnel involved in ERCP fluoroscopy and its reduction through equipment and behavior modifications, Am. J. Gastroenterol., 1997, vol. 97 4(pg. 893-897en_US
dc.identifier.doihttps://doi.org/10.1093/rpd/ncq353
dc.identifier.otherhttps://doi.org/10.1093/rpd/ncq353
dc.identifier.urihttps://t.ly/NM8lO
dc.language.isoenen_US
dc.publisherOxford University Pressen_US
dc.relation.ispartofseriesRadiation protection dosimetry;Volume 144, Issue 1-4, March 2011, Pages 530–533
dc.subjectendoscopicen_US
dc.subjectretrogradeen_US
dc.subjectcholangiopancreatographyen_US
dc.subjectSudanen_US
dc.titleOccupational exposure to staff during endoscopic retrograde cholangiopancreatography in Sudanen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
avatar_scholar_256.png
Size:
6.31 KB
Format:
Portable Network Graphics
Description:
Faculty Of Engineering Research Paper

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
51 B
Format:
Item-specific license agreed upon to submission
Description: