The mechanical complications of platform switching connection of implant-supported restorations: A systematic review and meta-analysis

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorFarid, KA
dc.contributor.authorHalim, CH
dc.contributor.authorKatamish, HA
dc.contributor.authorSalama, AA
dc.date.accessioned2020-03-12T07:48:54Z
dc.date.available2020-03-12T07:48:54Z
dc.date.issued2019-09
dc.descriptionWOS:000511993000001en_US
dc.description.abstractAim Platform implant abutment connection proved success in preserving crestal bone around implants, but the increased stress concentration on the prosthetic components is still a question. The primary aim of this systematic review was to evaluate the available evidence on the mechanical effect of implant platform switching concept on implant prosthetic components. Methods A protocol of electronic and hand research was performed for English based researches comparing one or more PS groups with one or more PM groups to develop an answer for the following question: "Will the platform switching technique affect the amount of stresses generated within implant prosthetic components causing mechanical complications? A meta-analysis was performed to evaluate the impact of implant-abutment platform mismatch on implant prosthetic components. Results Eleven publications from twenty research studies were included. Results from the meta-analysis demonstrated the odds of survival in the Platform matching connection arm are 2.13 times more compared to the Platform switching arm. (P-value=0.0316) For the random effects model, the odds of survival in the PS arm is not statistically significantly different compared to the PM arm (p-value=0.2224) due to substantial heterogeneity of the included studies results in regards to implant prosthetic components mechanical complications. Conclusion This systematic review showed higher stress concentration in the implant prosthetic components regarding using platform switched implants, more randomized controlled clinical trials with bigger samples are needed to confirm our findings, but the current evidence demonstrates that nonsignificant differences between platform switching concept and platform matching. It is recommended to further investigate the mechanical complications that might arise when platform switching concept is used.en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=21100226806&tip=sid&clean=0
dc.identifier.doihttps://doi.org/10.23805/JO.2019.11.03.03
dc.identifier.issn2036-413X
dc.identifier.otherhttps://doi.org/10.23805/JO.2019.11.03.03
dc.identifier.urihttps://t.ly/MRxq0
dc.language.isoen_USen_US
dc.publisherARIESDUE SRLen_US
dc.relation.ispartofseriesJOURNAL OF OSSEOINTEGRATION;Volume: 11 Issue: 3
dc.subjectuniversity of Implant platform switchingen_US
dc.subjectImplant-abutment mismatchen_US
dc.subjectDental abutmenten_US
dc.subjectMechanical complicationsen_US
dc.subjectLOAD FATIGUE PERFORMANCEen_US
dc.subjectSTRESS-DISTRIBUTIONen_US
dc.subjectPOSTERIOR REGIONen_US
dc.subjectBIOMECHANICAL EVALUATIONen_US
dc.subjectABUTMENT CONNECTIONSen_US
dc.subjectFAILURE MODESen_US
dc.titleThe mechanical complications of platform switching connection of implant-supported restorations: A systematic review and meta-analysisen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
avatar_scholar_256.png
Size:
6.31 KB
Format:
Portable Network Graphics
Description:
Loading...
Thumbnail Image
Name:
274-Article Text-1426-3-10-20190702.pdf
Size:
382.15 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
51 B
Format:
Item-specific license agreed upon to submission
Description: