Improving performance of tubular solar still by controlling the water depth and cover cooling

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorKabeel, AB
dc.contributor.authorW Sharshir, Swellam
dc.contributor.authorB Abdelaziz, Gamal
dc.contributor.authorA Halim, M
dc.contributor.authorSwidan, Ahmed
dc.date.accessioned2019-11-06T07:43:37Z
dc.date.available2019-11-06T07:43:37Z
dc.date.issued2019
dc.description.abstractRecently, tubular solar still (TSS) is considered as one of the preferable options for pure acquisition water, particularly, for small applications located in coastal and arid regions. Such areas are usually doesn't have a sufficient power source for water desalination or infrastructure to transport pure water. This paper presents an improvement in the daily rate of water production by offering TSS integrated with cover cooling. The system consists of a transparent solar tube to increase the amount of solar irradiance, which is combined with a black basin to enhance the absorption and improve the water evaporation. TSS was manufactured using lightweight materials, gaining strong and durable weight, from locally available materials. In this study, different basin water depth (0.5, 1, 2, and 3 cm) were investigated to obtain the best water depth. Furthermore, trying various water cover cooling flow rate (1, 2, 3, and 4 L/h) to get the optimal water-cooling flow rate. The experimental results show that the TSS with lower water depth gives the best performance, where the productivity was reached to 4.5 L/m(2), while with the large water depth at 3 cm give a daily productively of 3 L/m(2). Also, the best cooling water flow rate was obtained at 2 L/h. Under the best conditions corresponding to 0.5 cm water depth and 2 L/h cooling water flow rate, the maximum efficiency was achieved, which was about 54.9%. In comparison with TSS without cooling, the proposed TSS successfully improved the yield and efficiency of the TSS by about 31.4% and 32.6%, respectively. Moreover, the daily thermal exergy efficiency increased by about 9%. From an economic point of view, the cost per liter of clean water output was found to be 0.023 $ and 0.019 $ for TSS without and with cover cooling, respectively. (C) 2019 Elsevier Ltd. All rights reserveen_US
dc.description.sponsorshipELSEVIERen_US
dc.identifier.doihttps://doi.org/10.1016/j.jclepro.2019.06.104
dc.identifier.issn0959-6526
dc.identifier.issn1879-1786
dc.identifier.otherhttps://doi.org/10.1016/j.jclepro.2019.06.104
dc.identifier.urihttps://cutt.ly/EeTCXPF
dc.language.isoenen_US
dc.publisherELSEVIERen_US
dc.relation.ispartofseriesJOURNAL OF CLEANER PRODUCTION;Volume: 233 Pages: 848-856
dc.relation.urihttps://cutt.ly/JeTf0Xn
dc.subjectUniversity for Solar desalinationen_US
dc.subjectTubular solar stillen_US
dc.subjectWater depthen_US
dc.subjectCooling water flow rateen_US
dc.subjectThermal performanceen_US
dc.subjectPHASE-CHANGE MATERIALen_US
dc.subjectHUMIDIFICATION-DEHUMIDIFICATIONen_US
dc.subjectGRAPHITE NANOPARTICLESen_US
dc.subjectECONOMIC-ANALYSESen_US
dc.subjectEXERGY ANALYSISen_US
dc.subjectMASS-TRANSFERen_US
dc.subjectENERGYen_US
dc.subjectSYSTEMen_US
dc.subjectENHANCEMENTen_US
dc.subjectEFFICIENCYen_US
dc.titleImproving performance of tubular solar still by controlling the water depth and cover coolingen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
avatar_scholar_256.png
Size:
6.31 KB
Format:
Portable Network Graphics
Description: