Accuracy of ceramic restorations made with two CAD/CAM systems

dc.AffiliationOctober University for modern sciences and Arts (MSA)
dc.contributor.authorHamza T.A.
dc.contributor.authorEzzat H.A.
dc.contributor.authorEl-Hossary M.M.K.
dc.contributor.authorEl Megid Katamish H.A.
dc.contributor.authorShokry T.E.
dc.contributor.authorRosenstiel S.F.
dc.contributor.otherCrown and Fixed Prosthodontics Department
dc.contributor.otherFaculty of Dental Medicine
dc.contributor.otherAl-Azhar University
dc.contributor.otherCairo
dc.contributor.otherEgypt; Crown and Fixed Prosthodontics Department
dc.contributor.otherFaculty of Dental Medicine
dc.contributor.otherMSA University
dc.contributor.other6th of October City
dc.contributor.otherEgypt; Crown and Fixed Prosthodontics Department
dc.contributor.otherFaculty of Oral and Dental Medicine
dc.contributor.otherCairo University
dc.contributor.otherCairo
dc.contributor.otherEgypt; Division of Restorative and Prosthetic Dentistry
dc.contributor.otherCollege of Dentistry
dc.contributor.otherOhio State University
dc.contributor.otherColumbus
dc.contributor.otherOH
dc.contributor.otherUnited States
dc.date.accessioned2020-01-09T20:42:28Z
dc.date.available2020-01-09T20:42:28Z
dc.date.issued2013
dc.descriptionScopus
dc.description.abstractStatement of problem Different types of CAD/CAM systems are currently available, but information regarding which system produces the best marginal fit is lacking. Purpose The purpose of this study was to evaluate the effect of 2 different CAD/CAM systems (Cerec inLab, Kavo Everest) on the marginal fit of 2 types of zirconia-based and lithium disilicate crowns. Material and methods Forty zirconia-based and lithium disilicate crowns, 20 each, were fabricated with the Cerec inLab and Everest CAD/CAM systems on a specially designed stainless steel die to ensure the standardization of specimen shape and dimensions. The vertical marginal fit for all tested crowns was evaluated by using a digital microscope at �100 magnification, and the data were tabulated and statistically analyzed with 2-way ANOVA, followed by the Tukey honestly significant difference (HSD) test with a confidence level of.05 to determine the mean differences. Results The results showed that the CAD/CAM technique, ceramic type, and their interaction had a statistically significant effect on the mean marginal fit of both ceramic types tested. Conclusions Better marginal fit values were exhibited by the Everest CAD/CAM technique for both ceramic types tested. � 2013 The Editorial Council of the Journal of Prosthetic Dentistry.en_US
dc.description.urihttps://www.scimagojr.com/journalsearch.php?q=26175&tip=sid&clean=0
dc.identifier.doihttps://doi.org/10.1016/S0022-3913(13)60020-7
dc.identifier.doiPubMed ID : 23395333
dc.identifier.issn223913
dc.identifier.otherhttps://doi.org/10.1016/S0022-3913(13)60020-7
dc.identifier.otherPubMed ID : 23395333
dc.identifier.urihttps://t.ly/6xxEB
dc.language.isoEnglishen_US
dc.relation.ispartofseriesJournal of Prosthetic Dentistry
dc.relation.ispartofseries109
dc.subjectdental porcelainen_US
dc.subjectIPS e.max CAD LTen_US
dc.subjectlithia disilicateen_US
dc.subjectstainless steelen_US
dc.subjectyttria stabilized tetragonal zirconiaen_US
dc.subjectyttriumen_US
dc.subjectzirconiumen_US
dc.subjectzirconium oxideen_US
dc.subjectarticleen_US
dc.subjectchemistryen_US
dc.subjectcomputer aided designen_US
dc.subjectdental procedureen_US
dc.subjectdental surgeryen_US
dc.subjectendodonticsen_US
dc.subjectequipmenten_US
dc.subjectevaluationen_US
dc.subjecthumanen_US
dc.subjectmicroscopyen_US
dc.subjectstandarden_US
dc.subjectsurface propertyen_US
dc.subjecttooth crownen_US
dc.subjecttooth prosthesisen_US
dc.subjectComputer-Aided Designen_US
dc.subjectCrownsen_US
dc.subjectDental Marginal Adaptationen_US
dc.subjectDental Modelsen_US
dc.subjectDental Porcelainen_US
dc.subjectDental Prosthesis Designen_US
dc.subjectHumansen_US
dc.subjectMicroscopyen_US
dc.subjectStainless Steelen_US
dc.subjectSurface Propertiesen_US
dc.subjectTooth Preparation, Prosthodonticen_US
dc.subjectYttriumen_US
dc.subjectZirconiumen_US
dc.titleAccuracy of ceramic restorations made with two CAD/CAM systemsen_US
dc.typeArticleen_US
dcterms.isReferencedByChristensen, G.J., Esthetic dentistry-2008 (2008) Alpha Omegan, 101, pp. 69-70; Raigrodski, A.J., Contemporary materials and technologies for all-ceramic fixed partial dentures: A review of the literature (2004) J Prosthet Dent, 92, pp. 557-562; Conrad, H.J., Seong, W.J., Pesun, I.J., Current ceramic materials and systems with clinical recommendations: A systematic review (2007) J Prosthet Dent, 98, pp. 389-404; Beuer, F., Schweiger, J., Edelhoff, D., Digital dentistry: An overview of recent developments for CAD/CAM generated restorations (2008) Br Dent J, 204, pp. 505-511; Beschnidt, S.M., Strub, J.R., Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth (1999) J Oral Rehabil, 26, pp. 582-593; Beuer, F., Neumeier, P., Naumann, M., Marginal fit of 14-unit zirconia fixed dental prosthesis retainers (2009) J Oral Rehabil, 36, pp. 142-149; Gonzalo, E., Su�rez, M.J., Serrano, B., Lozano, J.F., Comparative analysis of two measurement methods for marginal fit in metal-ceramic and zirconia posterior FPDs (2009) Int J Prosthodont, 22, pp. 374-377; Groten, M.S., Girthofer, S., Probster, L., Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitro (1997) J Oral Rehabil, 24, pp. 871-881; Gassino, G., Barone Monfrin, S., Scanu, M., Spina, G., Preti, G., Marginal adaptation of fixed prosthodontics: A new in vitro 360-degree external examination procedure (2004) Int J Prosthodont, 17, pp. 218-223; Luthardt, R.G., Bornemann, G., Lemelson, S., Walter, M.H., H�ls, A., An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing (2004) Int J Prosthodont, 17, pp. 680-685; Shokry, T.E., Attia, M., Mosleh, I., Elhosary, M., Hamza, T., Shen, C., Effect of metal selection and porcelain firing on the marginal accuracy of titanium-based metal ceramic restorations (2010) J Prosthet Dent, 103, pp. 45-52; Wolfart, S., Wegner, S.M., Al-Halabi, A., Kern, M., Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation (2003) Int J Prosthodont, 16, pp. 587-592; Shearer, B., Gough, M.B., Setchell, D.J., Influence of marginal configuration and porcelain addition on the fit of In-Ceram crowns (1996) Biomaterials, 17, pp. 1891-1895; Chan, C., Haraszthy, G., Geis-Gerstofer, J., Weber, H., The marginal fit of Cerestore full-ceramic crowns-A preliminary report (1985) Quintessence Int, 6, pp. 399-402; Sorensen, J.A., A standardized method for determination of crown margin fidelity (1990) J Prosthet Dent, 64, pp. 18-24; Rink, S., H�ls, A., Jahn, L., Marginal accuracy and fracture strength of conventional and copy-milled all-ceramic crowns (1995) Int. J. Prosthodont, 8, pp. 303-310; Nakamura, T., Nonaka, M., Maruyama, T., In vitro fitting accuracy of copy-milled alumina cores and All-Ceramic Crowns (2000) Int J Prosthodont, 13, pp. 189-193; Rosentritt, M., Plein, T., Kolbeck, C., Behr, M., Handel, G., In vitro fracture force and marginal adaptation of ceramic crowns fixed on natural and artificial teeth (2000) Int J Prosthodont, 13, pp. 387-391; Grenade, C., Mainjot, A., Vanheusden, A., Fit of single tooth zirconia copings: Comparison between various manufacturing processes (2011) J Prosthet Dent, 105, pp. 249-255; Gonzalo, E., Su�rez, M.J., Serrano, B., Lozano, J.F., A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation (2009) J Prosthet Dent, 102, pp. 378-384; Gu, X.H., Kern, M., Gu, X.H., Kern, M., Marginal discrepancies and leakage of all-ceramic crowns: Influence of luting agents and aging conditions (2003) Int J Prosthodont, 16, pp. 109-116; Albert, F.E., El-Mowafy, O.M., Marginal adaptation and microleakage of Procera AllCeram crowns with four cements (2004) Int J. Prosthodont, 17, pp. 529-535; Quintas, A.F., Oliveira, F., Bottino, M.A., Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: An in vitro evaluation (2004) J Prosthet Dent, 92, pp. 250-257; Kokubo, Y., Ohkubo, C., Tsumita, M., Miyashita, A., Volt Von Steyern, P., Fukushima, S., Clinical marginal and internal gaps of Procera AllCeram crowns (2005) J Oral Rehabil, 32, pp. 526-530; Delong, R., Heinzen, M., Hodges, J.S., Ko, C.C., Douglas, W.H., Accuracy of a system for creating 3D computer models (2003) J Dent Res, 82, pp. 438-442; Cho, H.D., Jun, Y.T., Yung, M.Y., Five axis CNC milling for effective machining of sculptured surfaces (1993) Int J Prod Res, 31, pp. 2559-2573; Giannetopoulos, S., Van Noort, R., Tsitrou, E., Evaluation of the marginal integrity of ceramic copings with different marginal angles using two different CAD/CAM systems (2010) J Dent, 38, pp. 980-986
dcterms.sourceScopus

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
avatar_scholar_128.png
Size:
2.73 KB
Format:
Portable Network Graphics
Description: