Browsing by Author "Hegazy, MA"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item Green liquid chromatographic methods with ultraviolet and tandem mass spectrometry detection: An application to ternary mixture of paracetamol, pseudoephedrine, and cetirizine in capsule.(NCBI, 07/08/2019) Badawey, A; Hegazy, MA; Mohamed, D; Youssef, SHBackground: Effective chromatographic methods were developed for the determination of a multicomponent capsule prescribed for treating the common cold. Greening approaches were adopted as opposed to conventional methods. Objectives: Two novel, green chromatographic methods were established to quantitatively analyze the combination. Methods: First, an HPLC/UV method utilizing green solvents (water and ethanol) and acetic acid to adjust pH at 5 was accomplished. The stationary phase was a ZorbaxSB-C18 column (150 × 4.6 mm, 5 μm), and peaks were detected at 215 nm. The second method is a highly sensitive ultra-performance LC (UPLC)-MS/MS method in which the greening approach was established through the reduction of the analysis time (2 min), decreased solvent consumption (flow rate 300 μL/min), and the utilization of a small volume of samples (injection volume 2 μL). The mixture was separated using a UPLC-BEH C18 column (50 × 2.1 mm, 1.7 μm) with an isocratic elution using methanol–0.1% formic acid aqueous solution (60+40, v/v) as mobile phase and utilizing diphenhydramine as an internal standard. Positive-ion electrospray ionization and multiple reaction monitoring were applied for detection. Results: Recovery percentages for paracetamol, pseudoephedrine, and cetirizine were 101.70 ± 0.969, 100.18 ± 1.563, and 99.67 ± 1.429 for the HPLC method and 99.18 ± 1.172, 100.03 ± 0.883, and 99.82 ± 0.912 for the UPLC-MS/MS method, respectively. Conclusions: The proposed methods efficiently analyzed paracetamol, pseudoephedrine, and cetirizine in Allercet Cold® capsules. Validation of the proposed methods was in accordance with the International Conference on Harmonization recommendations, and statistical comparison with the reported method displayed no significant difference regarding accuracy and precision. Highlights: Paracetamol, pseudoephedrine, and cetirizine were successfully quantified using two chromatographic methods. The HPLC method developed is considered green, using water and ethanol as a mobile phase. The UPLC-MS/MS method was rapid and determined the three drugs with accuracy at nanogram levels.Item Liquid chromatography-tandem MS/MS method for simultaneous quantification of paracetamol, chlorzoxazone and aceclofenac in human plasma: An application to a clinical pharmacokinetic study(WILEY, 2018-07) Helmy, MI; Toubar, SS; Elshahed, MS; Hegazy, MA; Mohamed, DA facile, fast and specific method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous quantitation of paracetamol, chlorzoxazone and aceclofenac in human plasma was developed and validated. Sample preparation was achieved by liquid-liquid extraction. The analysis was performed on a reversed-phase C-18 HPLC column (5m, 4.6x50mm) using acetonitrile-10mM ammonium formate pH3.0 (65:35, v/v) as the mobile phase where atrovastatin was used as an internal standard. A very small injection volume (3L) was applied and the run time was 2.0min. The detection was carried out by electrospray positive and negative ionization mass spectrometry in the multiple-reaction monitoring mode. The developed method was capable of determining the analytes over the concentration ranges of 0.03-30.0, 0.015-15.00 and 0.15-15.00g/mL for paracetamol, chlorzoxazone and aceclofenac, respectively. Intraday and interday precisions (as coefficient of variation) were found to be 12.3% with an accuracy (as relative error) of +/- 5.0%. The method was successfully applied to a pharmacokinetic study of the three analytes after being orally administered to six healthy volunteers