Development and validation of simultaneous spectrophotometric and TLC-spectrodensitometric methods for determination of beclomethasone dipropionate and salbutamol in combined dosage form

Show simple item record

dc.contributor.author Samir A.
dc.contributor.author Lotfy H.M.
dc.contributor.author Salem H.
dc.contributor.author Abdelkawy M.
dc.contributor.other Analytical Chemistry Department
dc.contributor.other Faculty of Pharmacy
dc.contributor.other Cairo University
dc.contributor.other Egypt; Analytical Chemistry Department
dc.contributor.other Faculty of Pharmacy
dc.contributor.other October University for Modern Sciences and Arts
dc.contributor.other Egypt
dc.date.accessioned 2020-01-09T20:42:07Z
dc.date.available 2020-01-09T20:42:07Z
dc.date.issued 2014
dc.identifier.issn 13861425
dc.identifier.other https://doi.org/10.1016/j.saa.2014.02.044
dc.identifier.other PubMed ID 24662761
dc.identifier.uri https://t.ly/xR2Ze
dc.description Scopus
dc.description.abstract Spectrophotometric and TLC-spectrodensitometric methods were developed and validated for the simultaneous determination of beclomethasone dipropionate (BEC) and salbutamol (SAL). The spectrophotometric methods include dual wavelength, ratio difference, constant center coupled with a novel method namely, spectrum subtraction and mean centering with mean percentage recoveries and RSD 99.72 � 1.07 and 99.70 � 1.12, 100.25 � 1.12 and 99.89 � 1.12, 99.66 � 1.85 and 99.19 � 1.32, 100.74 � 1.26 and 101.06 � 0.90 for BEC and SAL respectively. The TLC-spectrodensitometric method was based on separation of both drugs on TLC aluminum plates of silica gel 60 F254, using benzene: methanol: triethylamine (10:1.5:0.5 v/v/v) as a mobile phase, followed by densitometric measurements of their bands at 230 nm. The mean percentage recoveries and RSD were 99.07 � 1.25 and 101.35 � 1.50 for BEC and SAL respectively. The proposed methods were validated according to ICH guidelines and were applied for the simultaneous analysis of the cited drugs in synthetic mixtures and pharmaceutical preparation. The methods were found to be rapid, specific, precise and accurate and can be successfully applied for the routine analysis of BEC and SAL in their pharmaceutical formulation with no need for prior separation. The results obtained were statistically compared to each other and to that of the reported HPLC method. The statistical comparison showed that there is no significant difference regarding both accuracy and precision. � 2014 Elsevier B.V. All rights reserved. en_US
dc.description.uri https://www.scimagojr.com/journalsearch.php?q=24530&tip=sid&clean=0
dc.language.iso English en_US
dc.publisher Elsevier en_US
dc.relation.ispartofseries Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
dc.relation.ispartofseries 128
dc.subject Beclomethasone dipropionate en_US
dc.subject Constant center en_US
dc.subject Mean centering en_US
dc.subject Ratio difference en_US
dc.subject Salbutamol en_US
dc.subject Spectrum subtraction en_US
dc.subject Silica gel en_US
dc.subject Spectrophotometers en_US
dc.subject Beclomethasone dipropionate en_US
dc.subject Constant center en_US
dc.subject Mean centering en_US
dc.subject Ratio differences en_US
dc.subject Salbutamol en_US
dc.subject Spectrum subtractions en_US
dc.subject Spectrophotometry en_US
dc.subject beclometasone en_US
dc.subject salbutamol en_US
dc.subject procedures en_US
dc.subject spectrophotometry en_US
dc.subject thin layer chromatography en_US
dc.subject Albuterol en_US
dc.subject Beclomethasone en_US
dc.subject Chromatography, Thin Layer en_US
dc.subject Spectrophotometry en_US
dc.title Development and validation of simultaneous spectrophotometric and TLC-spectrodensitometric methods for determination of beclomethasone dipropionate and salbutamol in combined dosage form en_US
dc.type Article en_US
dcterms.isReferencedBy Undem, B.J., (2006) Goodman & Gilman's the Pharmacological Basis of Therapeutics, , Laurence L. Brunton (Ed.) 11th ed., McGraw-Hill; �ati�nsk�, D., Karli�?ek, R., Svoboda, A.N., (2002) Anal. Chim. Acta, 455, pp. 103-109; Mohamed, G.G., Khalilet, S.M., Zayed, M.A., (2002) J. Pharm. Biomed. Anal., 28 (6), pp. 1127-1133; Bakry, R.S., El Walily, A.F., Belal, S.F., (1995) Polymer - Plastics Technol. Eng., 28 (14), pp. 2503-2519; Habib, I.H., Hassouna, M., Zaki, G., (2005) Il Farmaco, 60 (3), pp. 249-254; Dol, I., Knochen, M., (2004) Talanta, 64 (5), pp. 1233-1236; Sane, R., Nayak, V., Malkar, V., (1985) Talanta, 32 (1), pp. 31-33; El-Enany, N., Belal, F., Rizk, M., (2004) Chem. Anal. (Warsaw), 49 (2), pp. 261-269; Chitlange, S.S., Kaushalendra, C., Sneha, R.T., Sagar, W.B., (2011) Asian J. Res. Chem., 4 (5), pp. 786-790; Tan, Y.K., Soldin, S.J., (1984) J. Chromatogr. B: Biomed. Sci. Appl., 311, pp. 311-317; Murtaza, G., Ahmed, M., Madni, M.A., Asghar, M.W., (2009) Bull. Chem. Soc. Ethiopia, 23 (1), pp. 1-8; Maithani, M., (2011) J. Anal. Bioanal. Techniques, 2 (1), pp. 1-5; Bazylak, G., Nagels, L.J., (2003) J. Pharm. Biomed. Anal., 32 (4), pp. 887-903; Ackermans, M.T., Beckers, J.L., Everaerts, F.M., Seelen, I.G.J.A., (1992) J. Chromatogr. A, 590 (2), pp. 341-353; Sagar, K.A., Kelly, M.T., Smyth, M.R., (1993) Biomed. Chromatogr., 7 (1), pp. 29-33; Aboul-Enein, H.Y., Abu-Zaid, S., (2001) Anal. Lett., 34 (12), pp. 2099-2110; Altria, K., (1993) J. Chromatogr. A, 634 (2), pp. 323-328; Yilmaz, N., Ozkan, S.A., Senturk, B.U., Biryol, I., (1998) Turkish J. Chem., 22, pp. 175-182; Sagar, K.A., Smyth, M.R., Munden, R., (1993) J. Pharm. Biomed. Anal., 11 (7), pp. 533-540; Goyal, R.N., Oyama, M., Singh, S.P., (2007) J. Electroanal. Chem., 611 (1), pp. 140-148; Blanco, M., Serrano, D., Bernal, J., (1999) Talanta, 50 (3), pp. 527-532; Bernal, J., Del Nozal, M.J., Martin, M.T., Diez-Masa, J.C., Cefuentes, A., (1998) J. Chromatogr. A, 823 (1), pp. 423-431; De Orsi, D., Gagliardi, L., Chimenti, F., Tonelli, D., (1995) Anal. Lett., 28 (9), pp. 1655-1663; Shou, M., Galinada, W.A., Wei, Y., Tang, Q., Markovich, R.J., Rustum, A.M., (2009) J. Pharm. Biomed. Anal., 50 (3), pp. 356-361; Martis, E.A., Gangrade, D.M., (2011) Int. J. Pharm. Sci., 3, pp. 64-67; Hackmann, E., Benetton, S., Santoro, M., (1991) J. Pharm. Pharmacol., 43 (4), pp. 285-287; Sane, R.T., Bhate, V.R., Nayak, V.G., Tendolkar, R.V., Gangal, D.P., (1990) Indian Drugs, 28 (2), pp. 90-93; Hellea, A., Hirsj�rvib, S.I., Peltonenb, L., Hirvonenb, J., Wiedme, S.K., (2008) J. Chromatogr. A, 1178 (12), pp. 248-255; Lotfy, H.M., Saleh, S.S., Hassan, N.Y., Elgizawy, S.M., (2012) Am. J. Anal. Chem., 3 (11), pp. 761-769; Lotfy, H.M., Hegazy, M.M., (2013) Spectrochim. Acta Part A Mol. Biomol. Spectrosc., 113, pp. 107-114; Lotfy, H.M., Hegazy, M.M., (2012) Spectrochim. Acta Part A Mol. Biomol. Spectrosc., 96, pp. 259-327; Lotfy, H.M., Monir, H.H., Abdel-Aleem, A., (2012) J. Chilean Chem. Soc., 57 (4), pp. 1199-1207; Lotfy, H.M., Hassan, N.Y., Elgizawy, S.M., Saleh, S.S., (2013) J. Chilean Chem. Soc., 58 (3), pp. 1651-1657; Lotfy, H.M., (2012) Inter. J. Pharm. Pharm. Sci., 4 (4), pp. 673-679; Lotfy, H.M., Saleh, S.S., Hassan, N.Y., Elgizawy, S.M., (2013) Anal. Chem. Lett., 3 (2), pp. 70-78; (2005) Q2B: Validation of Analytical Procedures: Methodology, 62. , International Conference on Harmonization, (ICH) US FDA, Federal Register; (1994) Validation of Chromatographic Methods - Reviewer Guidance, , Center for Drug Evaluation and Research FDA
dcterms.source Scopus
dc.identifier.doi https://doi.org/10.1016/j.saa.2014.02.044
dc.identifier.doi PubMed ID 24662761
dc.Affiliation October University for modern sciences and Arts (MSA)