Column performance study of different variants of liquid chromatographic technique: An application on pharmaceutical ternary mixtures containing tetryzoline

Show simple item record

dc.contributor.author Salem H.
dc.contributor.author Hassan N.Y.
dc.contributor.author Lotfy H.M.
dc.contributor.author Saleh S.S.
dc.contributor.other Analytical Chemistry Department
dc.contributor.other Faculty of Pharmacy
dc.contributor.other October University for Modern Sciences and Arts (MSA)
dc.contributor.other 6th October City
dc.contributor.other 11787
dc.contributor.other Egypt; Analytical Chemistry Department
dc.contributor.other Faculty of Pharmacy
dc.contributor.other Cairo University
dc.contributor.other Kasr-El Aini Street
dc.contributor.other Cairo
dc.contributor.other 11562
dc.contributor.other Egypt
dc.date.accessioned 2020-01-09T20:41:58Z
dc.date.available 2020-01-09T20:41:58Z
dc.date.issued 2015
dc.identifier.issn 219665
dc.identifier.other https://doi.org/10.1093/chromsci/bmu109
dc.identifier.other PubMed ID :
dc.identifier.uri https://t.ly/DXZpY
dc.description Scopus
dc.description.abstract High-performance liquid chromatography (HPLC), ultra-performance liquid chromatography (UPLC) and rapid resolution liquid chromatographic (RRLC) methods have been developed and validated for the separation and quantitation of both or either of two ternary mixtures present in ophthalmic solutions. The first mixture contains chloramphenicol, dexamethasone sodium phosphate and tetryzoline HCl (TZH); while the second one contains ofloxacin, prednisolone acetate and TZH. Both preparations contain benzalkonium chloride as a preservative. The columns used were a HPLC column (C<inf>18</inf> 5 ?m particle size), a RRLC column (C<inf>18</inf> 2.6 ?m particle size) and a UPLC column (C<inf>18</inf> 1.7 ?m particle size). A comparative study was conducted to illustrate the effect of the change in column particle size and dimensions on the other chromatographic conditions, backpressure and the separation of both ternary mixtures. The methods were validated as per ICH guidelines where accuracy, repeatability, interday precision and robustness were found to be within the acceptable limits. The RRLC column provided shorter run time and better resolution than HPLC, while the UPLC column gave the shortest run time for all columns. The RRLC column resulted in minimum backpressure, so it could be used with any HPLC instrument, which makes the method more practical and economic. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed. � The Author 2014. Published by Oxford University Press. en_US
dc.description.uri https://www.scimagojr.com/journalsearch.php?q=24023&tip=sid&clean=0
dc.language.iso English en_US
dc.publisher Oxford University Press en_US
dc.relation.ispartofseries Journal of Chromatographic Science
dc.relation.ispartofseries 53
dc.subject جامعة أكتوبر للعلوم الحديثة والآداب
dc.subject MSA University
dc.subject University for Modern Sciences and Arts
dc.subject October University for Modern Sciences and Arts
dc.title Column performance study of different variants of liquid chromatographic technique: An application on pharmaceutical ternary mixtures containing tetryzoline en_US
dc.type Article en_US
dcterms.isReferencedBy Antoniou, C.G., Markopoulou, C.K., Kouskoura, M.G., Koundourellis, J.E., Study and development of reversed-phase HPLC systems for the determination of 2-imidazolines in the presence of preservatives in pharmaceutical preparations (2011) Journal of AOAC International, 94, pp. 703-712; B�valot, F., Gaillard, Y., Lhermitte, M.A., P�pinm, G., Analysis of corticosteroids in hair by liquid chromatography-electrospray ionization mass spectrometry (2000) Journal of Chromatography B, 740, pp. 227-236; Idowu, O.R., Peggins, J.O., Simple, rapid determination of enrofloxacin and ciprofloxacin in bovine milk and plasma by high-performance liquid chromatography with fluorescence detection (2004) Journal of Pharmaceutical and Biomedical Analysis, 35, pp. 143-153; Elgizawy, S.M., Hassan, Y.N., Lotfy, H.M., Saleh, S.S., Comparative study of RP-HPLC versus TLC-spectrodensitometric methods applied for binary mixtures of fluoroquinolones and corticosteroids (2014) Acta Chromatographica, 26, pp. 439-456; Samir, A., Salem, H., Abdelkawy, M., Simultaneous determination of salmeterol xinafoate and fluticasone propionate in bulk powder and seritide diskus using high performance liquid chromatographic and spectrophotometric method (2012) Pharmaceutica Analytica Acta, 3, pp. 1-7; Fayed, A.S., Shehata, M.A., Ashour, A., Hassan, N.Y., Weshahy, S.A., Validated stability-indicating methods for determination of cilostazol in the presence of its degradation products according to the ICH guidelines (2007) Journal of Pharmaceutical and Biomedical Analysis, 45, pp. 407-416; El-Bardicy, M.G., Lotfy, H.M., El-Sayed, M.A., El-Tarras, M.F., Kinetic study of the degradation of meclophenoxate hydrochloride in alkaline aqueous solutions by high performance liquid chromatography (2007) The Pharmaceutical Society of Japan, 127, pp. 193-199; Nov�kov�, L., Matysov�, L., Solich, P., Advantages of application of UPLC in pharmaceutical analysis (2006) Talanta, 68, pp. 908-918; Liang, Y., Xie, P., Chanm, K., Quality control of herbal medicines (2004) Journal of Chromatography B, 812, pp. 53-70; Gumustas, M., Kurbanoglu, S., Uslu, B., Ozkan, S.A., UPLC versus HPLC on drug analysis: Advantageous, applications and their validation parameters (2013) Chromatographia, 76, pp. 1365-1427; �at�nsk�, D., J�gerov�, K., Havl�kov�, L., Solich, P., A new and fast HPLC method for determination of rutin, troxerutin, diosmin and hesperidin in food supplements using fused-core column technology (2013) Food Analytical Methods, 6, pp. 1353-1360; �at�nsk�, S., Kamen�?kov�, D., Chocholou�, P., Solich, P., Fast HPLC method for determination of fenoxycarb and permethrin in antiparasitic veterinary shampoo using fused-core column (2013) Chromatographia, 76, pp. 1559-1564; DeStefano, J.J., Langlois, T.J., Kirkland, J.J., Characteristics of superficially-porous silica particles for fast HPLC: Some performance comparisons with sub-2-mm particles (2008) Journal of Chromatographic Sciences, 46, pp. 254-260; Zhang, Y., Wang, X., Mukherjee, P., Petersson, P., Critical comparison of performances of superficially porous particles and sub-2 mm particles under optimized ultra-high pressure conditions (2009) Journal of Chromatography A, 1216, pp. 4597-4605; Yandamuri, N., Srinivas Nagabattula, K.R., Kurra, S.S., Batthula, S., Nainesha Allada, L.P.S., Bandam, P., Comparative study of new trends in HPLC: A review (2013) International Journal of Pharmaceutical Sciences Review and Research, 23, pp. 52-57; Gong, Q.J., Qiao, J.L., Du, L.M., Dong, D., Jin, W.J., Recognition and simultaneous determination of ofloxacin enantiomers by synchronization-1st derivative fluorescence spectroscopy (2000) Talanta, 53, pp. 359-365; Geffken, D., Salem, H., Spectrofluorimetric study of the chargetransfer complexation of certain fluoroquinolones with 2, 3, 5, 6- tetrafluoro-p-bezoquinone (2006) American Journal of Applied Sciences, 3, pp. 1952-1960; Li, W.Y., Chen, X.F., Xuan, C.S., Study of fluorescence characteristics of the charge-transfer reaction of quinolone agents with bromanil (2009) Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 71, pp. 1769-1775; Zivanovic, L., Zigic, G., Zecevic, M., Investigation of chromatographic conditions for the separation of ofloxacin and its degradation products (2006) Journal of Chromatography A, 1119, pp. 224-230; Shervington, L.A., Abba, M., Hussain, B., Donnelly, J., The simultaneous separation and determination of five quinolone antibiotics using isocratic reversed-phase HPLC: Application to stability studies on an ofloxacin tablet formulation (2005) Journal of Pharmaceutical and Biomedical Analysis, 39, pp. 769-775; Singh, D.K., Verma, R., Comparison of second derivative-spectrophotometric and reversed-phase HPLC methods for the determination of prednisolone in pharmaceutical formulations (2007) Analytical Sciences, 23, pp. 1241-1243; D�si, E., Kov�cs, �., Palotai, Z., Kende, A., Analysis of dexamethasone and prednisolone residues in bovine milk using matrix solid phase dispersion-liquid chromatography with ultraviolet detection (2008) Microchemical Journal, 89, pp. 77-81; Katakam, P., Sireesha, K.R., Stability indicating HPLC method for simultaneous determination of chloramphenicol and prednisolone acetate in bulk and formulations (2012) Asian Journal of Pharmaceutical and Clinical Research, 5, pp. 182-185; Razzaq, S.N., Khan, I.U., Mariam, I., Razzaq, S.S., Stability indicating HPLC method for the simultaneous determination of moxifloxacin and prednisolone in pharmaceutical formulations (2012) Chemistry Central Journal, 6, pp. 94-104; Musharraf, S.G., Fatima, U., Sultana, R., Stress degradation studies and development of stability-indicating TLC-densitometry method for determination of prednisolone acetate and chloramphenicol in their individual and combined pharmaceutical formulations (2012) Chemistry Central Journal, 6, pp. 7-18; Al-Rimawi, F., Kharoaf, M., Analysis of chloramphenicol and its related compound 2-amino-1-(4-nitrophenyl)propane-1, 3-diol by reversed-phase high-performance liquid chromatography with UV detection (2011) Chromatography Research International; Nepote, A.J., Damiani, P.C., Olivieri, A.C., Chemometrics assisted spectroscopic determination of vitamin B6, vitamin B12 and dexamethasone in injectables (2003) Journal of Pharmaceutical and Biomedical Analysis, 31, pp. 621-627; El-Yazbi, F.A., Hammud, H.H., Assi, S.A., New spectrofluorometric application for the determination of ternary mixtures of drugs (2006) Analytica Chimica Acta, 580, pp. 39-46; Al-Rimawi, F., Zareer, W., Rabie, S., Quod, M., Development and validation of a reversed-phase HPLC method for analysis of tetrahydrozoline hydrochloride in eye drop formulations (2012) Journal of Pharmaceutical Analysis, 2, pp. 67-70; Bekele, A., Hymete, A., Bekhit, A.A., Development and validation of HPTLC densitometric method for simultaneous determination of antazoline hydrochloride and tetryzoline hydrochloride in eye drop and its application as stability indicator (2013) Thai Journal of Pharmaceutical Sciences, 37, pp. 134-145; Lotfy, H.M., Saleh, S.S., Hassan, N.Y., Salem, H., A comparative study of novel spectrophotometric methods based on isosbestic points application on a pharmaceutical ternary mixture (2014) Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 126, pp. 112-121; Ali, M.S., Ghori, M., Saeed, A., Simultaneous determination of ofloxacin, tetrahydrozoline hydrochloride, and prednisolone acetate by highperformance liquid chromatography (2002) Journal of Chromatographic Sciences, 40, pp. 429-433; (2009) British Pharmacopoeia, , www.pharmacopoeia.co.uk; (2004) United States Pharmacopeia-National Formulary, , www.usp.org, in Bulletin of Hunan Medical University U.S.P. Commission, Editor; (1997) International Conference on Harmonization (ICH, 62, p. 96. , Q.B. Federal Register
dcterms.source Scopus
dc.identifier.doi https://doi.org/10.1093/chromsci/bmu109
dc.identifier.doi PubMed ID :
dc.Affiliation October University for modern sciences and Arts (MSA)


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search MSAR


Advanced Search

Browse

My Account