Adaptation of Hard Gelatin Capsules for Aqueous Solution Delivery Using Gamma Radiation

Show simple item record

dc.contributor.author Sakr, Tamer
dc.contributor.author Assaly, Mohamed K.
dc.contributor.author AbdelRashid, Rania S
dc.contributor.author Omar, Samia
dc.date.accessioned 2019-12-18T15:09:35Z
dc.date.available 2019-12-18T15:09:35Z
dc.date.issued 2017-10
dc.identifier.issn 2357-0547
dc.identifier.other https://doi.org/
dc.identifier.uri https://aprh.journals.ekb.eg/article_4882_4723a9891d10fc1068cc166667c7ccdd.pdf
dc.description.abstract Objective: Directly incorporating aqueous solutions into hard gelatin capsules (HGCs) without dispersing them in an oily medium is considered a challenge for most researchers and manufacturers. The aim of the study is to evaluate the effect of gamma radiation (ɣ-radiation) on the adaptation of HGCs for aqueous solution delivery. Methods: Empty HGC shells were exposed to four of ɣ-radiation doses (1, 3, 5, 10 kGy). Then, the physicochemical properties of irradiated capsules were evaluation and compared with those of non-irradiated capsules. Fourier-transform infrared spectroscopy (FT-IR), capsule hardness, and water incorporation tests were performed. In-vitro disintegration/dissolution behavior determined as (rupture time) in different dissolution media was evaluated. Results: The results showed direct proportionality between the ɣ-radiation dose and HGC crosslinking degree up to 3 kGy, while at doses >3 kGy, degradation rather than crosslinking occurred. The results were clearly demonstrated by FTIR as peptide linkages between gelatin molecules. All the ɣ-irradiated HGCs submitted to hardness test were completely deformed without rupture with increasing capsule deformation work (J) for γ-radiation doses up to 3 kGy; the deformation work declined at doses >3 kGy. The water incorporation study revealed that capsules exposed to 3 kGy could hold up to 100 ml of methylene blue solution without deformation or leakage for 45 minutes compared with non-irradiated HGCs, which showed a significantly lower tolerance of only 2 minutes (p<0.001). The crosslinking of HGCs had a minor significant effect on in-vitro rupture time, especially at gastric pH. Conclusion: The irradiation technique may be used not only for sterilizing HGCs but also for adapting HGCs for aqueous solutions delivery, as it showed a significant positive effect, which was optimal at a dose of 3 kGy. However, these results are not sufficient for scaled-up manufacturing; thus, further investigations are strongly recommended. en_US
dc.language.iso en_US en_US
dc.publisher JAPR en_US
dc.relation.ispartofseries Journal of advanced PHARMACY research;2 (1), 36-43
dc.subject Liquid-filled capsules en_US
dc.subject Hard gelatin capsules en_US
dc.subject Gamma radiation en_US
dc.subject Cross linking en_US
dc.title Adaptation of Hard Gelatin Capsules for Aqueous Solution Delivery Using Gamma Radiation en_US
dc.type Article en_US
dc.identifier.doi https://doi.org/
dc.Affiliation October University for modern sciences and Arts (MSA)


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search MSAR


Advanced Search

Browse

My Account