Effect of mist cooling technique on exergy and energy analysis of steam injected gas turbine cycle

Show simple item record

dc.contributor.author Abdala, Antar M. M.
dc.contributor.author Elwekeel, Fifi N. M
dc.date.accessioned 2019-12-02T07:48:26Z
dc.date.available 2019-12-02T07:48:26Z
dc.date.issued 04/05/2016
dc.identifier.issn 1359-4311
dc.identifier.other https://doi.org/10.1016/j.applthermaleng.2015.12.040
dc.identifier.uri https://www.sciencedirect.com/science/article/abs/pii/S1359431115014210
dc.description Accession Number: WOS:000373863000031 en_US
dc.description.abstract The common cogeneration application is steam injected gas turbine. By using cogeneration, it can be obtained with the greatest benefit from fuel energy. In steam injected gas turbine the heat of exhaust gases is used to produce the steam, and this steam injects to combustion chamber. In the present work, the generated steam not only will be directed to the combustion chamber but also will be used to cool the blade turbine by using a closed loop. In this study, the effect of addition mist to steam as coolant fluid was investigated. The energy and exergy analyses for steam injected gas turbine cycle with a closed loop cooling technique by using steam and steam/mist were investigated. The investigation was made at varied values of steam coolant temperature, mist fraction, mist temperature, pressure ratio, turbine inlet temperature and blade temperature. These parameters affected network, plant efficiency, energy ratio, fuel conversion ratio and exergy efficiency. The results show that the efficiency can reach 47.2% at low coolant temperature with a mist fraction of 2%. The coolant heat gain is enhanced at lower mist temperature, so the blade surface temperature can be improved with mist addition to steam. At a mist fraction of 2% exergy efficiency is decreased by 0.03% than that for exergy efficiency of steam only. (C) 2015 Elsevier Ltd. All rights reserved. en_US
dc.language.iso en_US en_US
dc.publisher PERGAMON-ELSEVIER SCIENCE LTD en_US
dc.relation.ispartofseries APPLIED THERMAL ENGINEERING;Volume: 98 Pages: 298-309
dc.relation.uri https://cutt.ly/ae9lHP6
dc.subject University for Cogeneration en_US
dc.subject Gas turbine en_US
dc.subject Closed loop cooling en_US
dc.subject Mist/steam en_US
dc.subject Exergy en_US
dc.subject Energy en_US
dc.subject INLET en_US
dc.subject PERFORMANCE en_US
dc.subject OPTIMIZATION en_US
dc.subject POWER-PLANT en_US
dc.title Effect of mist cooling technique on exergy and energy analysis of steam injected gas turbine cycle en_US
dc.type Article en_US
dc.identifier.doi https://doi.org/10.1016/j.applthermaleng.2015.12.040
dc.Affiliation October University for modern sciences and Arts (MSA)


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search MSAR


Advanced Search

Browse

My Account