3D Finite Element Study on Incomplete Osseointegration: Locator Attachment versus Ball Attachment

Show simple item record

dc.contributor.author ElGabry, Hisham S
dc.contributor.author Yousief, Salah A
dc.contributor.author Moubarak, Amal H
dc.contributor.author Eltaftazani, Iman A
dc.contributor.author El-Anwar, Mohamad
dc.contributor.author El-Zawahry, Mohamed M
dc.date.accessioned 2021-03-13T08:25:05Z
dc.date.available 2021-03-13T08:25:05Z
dc.date.issued 2021-02
dc.identifier.issn 18579655
dc.identifier.other 10.3889/oamjms.2021.5680
dc.identifier.uri http://repository.msa.edu.eg/xmlui/handle/123456789/4456
dc.description Scopus en_US
dc.description.abstract BACKGROUND: Incomplete implant osseointegration may affect the choice of the type of attachment to ensure less amount of bone resorption, periods of maintenance, and longer implant/attachment life-time. AIM: The aim of this study was to evaluate, using 3D FE analysis (FEA), the influence of two different types of attachments on the rate of bone resorption, need for maintenance and implant/attachment life time in cases of unpredictable osseointegration in various bone types and using different implant angulations. METHODS: Six finite element models were prepared; three for the locator attachment while the other three for the ball attachment. Each of the three models simulates vertical implant and inclined implants by 10° and 20° degrees. Frictional contact between implant and cortical bone simulated the incomplete osseointegration scenario. RESULTS: Non-linear static analysis results showed that locator attachment and its cap may have longer time life in comparison with the ball attachment and its cap. CONCLUSIONS: Both attachments were safe for cortical and spongy bone, while the cortical bone receives less Von Mises stress by up to 33% with the increased implant angulation. en_US
dc.description.uri https://www.scimagojr.com/journalsearch.php?q=21100824403&tip=sid&clean=0
dc.language.iso en_US en_US
dc.publisher Open Access Macedonian Journal of Medical Sciences en_US
dc.relation.ispartofseries Open Access Macedonian Journal of Medical Sciences;Volume 9, 2021, Pages 24-28
dc.subject Ball and Socket Attachment en_US
dc.subject Finite Element Analysis en_US
dc.subject Incomplete Osseointegration en_US
dc.subject Locator Attachment en_US
dc.title 3D Finite Element Study on Incomplete Osseointegration: Locator Attachment versus Ball Attachment en_US
dc.type Article en_US
dc.Affiliation October University for modern sciences and Arts (MSA)


Files in this item