M. El-Maraghy, ChristineSalem, HeshamM. Amer, SawsanNebsen, Marianne2019-10-272019-10-2720191. ICH-International Conference on Harmonization, of Technical Requirements for registration of Pharmaceuticals for Human Use Topic Q2 (R1), Validation of Analytical Procedures: Text and Methodology, Geneva, Switzerland, 2005. 2. Naber, D. and Lambert, M. (2004). Aripiprazole: a new atypical antipsychotic with a different pharmacological mechanism. Prog Neuropsychopharmacol Biol Psychiatry. 28(8): 1213-1219. 3. DeLeon, A., Patel, N.C. and Crismon, M.L. (2004). Aripiprazole: A comprehensive review of its pharmacology, clinical efficacy, and tolerability. Clin Therap. 26(5): 649-666. 4. Sweetman, S.C. (2005). Martindale” The Complete Drug Reference”. London, Pharmaceutical Press.p. 5. Mondal, P., Rani, S.S. and Alekhya, K. (2013). A new stability indicating validated method for the determination of Aripiprazole in bulk and tablet dosage form using RP- HPLC. Int J Pharm Pharm Sci. 5(4): 660-665. 6. Narayana, M.B.V. and Chandrasekhar, K.B. (2012). A Validated specific stability-indicating RP-HPLC method for Aripiprazole and its related substances. J Chem Pharm Res. 4(9): 4426- 4435. 7. Pai, N.R. and Dubhashi, D.S. (2010). Development of stability indicating, validated HPLC method for quantitative determination of Aripiprazole and its impurities. Der Pharmacia Lettre. 2 (4): 1-10. 8. Helmy, A.G., Abdel-Gawad, F.M. and Mohamed, E.F. (2012). Spectrophotometric study on determination of Aripiprazole in tablets by charge-transfer and ion-pair complexation reactions with some acceptors. Asian J. Pharm. Ana. 2(1): 12-19. 9. Jain, R.,. Kashaw, S.K., Jain, R., Mishra, P. and Kohli, D.V. (2011). Visible spectrophotometric method for the determination of Aripiprazole in tablets. Indian J Pharm Sci. 73(1): 74-76. 10. Kalaichelvi, R., Thangabalan, B., Rao, D.S. and Jayachandran, E. (2009). UV spectrophotometric determination of Aripiprazole in bulk and pharmaceutical formulation. E-J.Chem. 6(S1): S87-S90. 11. Sandeep, K., Induri, M. and Sudhakar, M. (2013). Validated spectrophotometric quantification of Aripiprazole in pharmaceutical formulations by using multivariate technique. Adv Pharm Bull. 3(2): 469-472. 12. Kalaichelvi, R., Thangabalan, B. and Rao, D.S. (2010). Validated RP-HPLC method for analysis of Aripiprazole in a formulation. E-J.Chem. 7(3): 827-832. 13. Kubo, M., Mizooku, Y., Hirao, Y. and Osumi, T. (2005). Development and validation of an LC-MS/MS method for the quantitative determination of Aripiprazole and its main metabolite, OPC-14857, in human plasma. J. Chromatogr. B. 822(1-2): 294-299. 14. Patel, D.P., Sharma, P., Sanyal, M. and Shrivastav, P.S. (2013). SPE-UPLC-MS/MS method for sensitive and rapid determination of Aripiprazole in human plasma to support a bioequivalence study. J. Chromatogr. B. 925: 20-25. 15. Asangil, D., Tasdemir, I.H. and Kiliç, E. (2012). Adsorptive stripping voltammetric methods for determination of Aripiprazole. J. Pharm. Anal. 2(3): 193-199. 16. Merli, D., Dondi, D., Ravelli, D., Tacchini, D. and Profumo, A. (2013). Electrochemistry and analytical determination of Aripiprazole and Octoclothepin at glassy carbon electrode.J. Electroanal. Chem. 711: 1-7. 17. M.Amer, S., El-Maraghy, C.M., Salem, H. and Nebsen, M. (2016). Quantitative determination of citalopram hydrobromide by spectrophotometry and chemometry in presence of its degradation products and additives in pharmaceutical preparation. Analytical Chemistry: An Indian Journal. 16(2): 53-62. 18. Miller, J.N. and Miller, J.C. (2005). Statistics and Chemometrics for Analytical Chemistry. England, Harlow, Pearson Education Limited.2231-1874https://doi.org/10.1080/22297928.2019.1585286https://t.ly/j7wyVMSA Google ScholarSimple, accurate, selective and validated stability indicating UV spectrophotometric univariate and multivariate methods were developed for determination of Aripiprazole in presence of its alkaline and oxidative degradation products. The developed univariate methods; derivative ratio spectra-zero crossing, successive derivatives of ratio spectra and mean centering of ratio spectra. The first one used the amplitude of the first derivative ratio signals at 303.0 nm, the second method depended on the successive derivative of ratio spectra in two steps and measuring the absorbance of Aripiprazole at 281.0 nm and the third one measured the mean centered values oat 294.0 nm. Two chemometric multivariate methods were applied; principal component regression (PCR) and partial least-squares regression (PLS). The selectivity of the proposed methods was confirmed using laboratory-prepared mixtures. The obtained results were statistically compared with those obtained with the manufacturer HPLC method, showing no significant difference with in accuracy and precision. These methods could be applied as stability indicating methods for the determination of Aripiprazole in presence of its degradation products, in bulk powder or in pharmaceutical formulations.enUniversity of AripiprazoleDegradationSpectrophotometryStability Indicating Spectrophotometric and Chemometric Methods for Determination of Aripiprazole in Presence of its Degradation Products, A Comparative StudyArticlehttps://doi.org/10.1080/22297928.2019.1585286